FIREPLACE
INSTALLATION
Continued
CHECK GAS TyPE
Use proper gas type for the fireplace unit you
are installing. If your gas supply is not correct,
do not install fireplace. See retailer where
you purchased fireplace for proper fireplace
according to your gas type or to purchase gas
conversion kit (see
Accessories
, page 39).
INSTALLING GAS pIpING TO
FIREpLACE LOCATION
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
CAUTION: For propane/LP
units, never connect fireplace di-
rectly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between
the fireplace and propane/LP
supply.
Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connec
-
tor (if allowed by local codes)
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al
-
ternative to test gauge connection. Purchase
the CSA design-certified equipment shutoff
valve from your retailer.
For propane/LP connection only, the installer
must supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not
reduce incoming gas pressure, fireplace
regulator damage could occur. Install external
regulator with the vent pointing down as shown
in Figure 37. Pointing the vent down protects it
from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to fireplace.
If pipe is too small, undue loss
of volume will occur.
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from fireplace (see
Figure 38, page 24).
IMPORTANT
: Install main gas valve (equip
-
ment shutoff valve) in an accessible location.
The main gas valve is for turning on or shutting
off the gas to the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged fireplace valves.
Figure 37 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP
Supply Tank
External
Regulator
With Vent
Pointing
Down