WARNING!
Material damage from incorrect installation!
Incorrectly laid cables could be damaged by mechanical influences such
as tension, friction or becoming jammed. Defective cables could cause
short circuits and electronic malfunctions, system failures or cable fires.
Cable fires or the failure of the assistance system could cause injuries
from fires or transport accidents.
–
Electrical connections and cable connections may only be carried out
by an electrician.
–
Protect the cable connections from damage.
–
Adhere to the prescribed maintenance intervals.
2.6
Safety markings
The hard stamping (and the article number it contains) identifies the version of the
VETTER Smart
Fork
®
upon delivery. VETTER Smart
Fork
®
fork arms without a marking
must not be put into operation. The VETTER Smart
Fork
®
hard stamping is on the side of
the back of the fork (Fig. 11).
NOTICE!
The use of the VETTER Smart
Fork
®
without the prescribed markings is
considered misuse.
Fig. 11: Hard stamping
A: Article number (optional)
t:
Carrying capacity
l:
Load centre
C: Material code
M: Material
V: Manufacturer marking
W: Week of manufacture
J: Year of manufacture
F: Production order number
Incorrect
cable connec-
tions
Hard stamping
Safety
Safety markings
V1.08/2019
SmartFork
®
- The intelligent SensorFork
20