VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
NR. PARAMETER
DESCRIPTION
»
THREAD CLAMP
100
Thread clamp (
5
)
The following function are available:
OFF
= Out of action.
ON
= In action.
The function of the thread clamp is equal to a thread wiper function. When the
point of the hook is catching the thread loop the clamp will close. The hook will
pull the beginning of the thread down through the material.
NR. PARAMETER
DESCRIPTION
»
BACKTACK TYPE
110
Stitch in stitch backtack
You can choose between:
OFF
= Out of action normal backtack.
ON
= In action stitch in stitch backtack.
With a normal backtack the direction is changed during the feeding. The penetra-
tion of the needle is not exactly on top of each other. Will be used for not visible
seams. The stitches will be exactly in the same position with the stitch in stitch
backtack. The feeding will be switched when the machine is standing still. It will
be used for visible backtacks with high quality.
05. PROGRAMMING
04.
PROGRAM PARAMETER
-10-14
120
backtack or condensed
stitches at seam start
135
bobbin thread counter
121
A stitch count
122
B stitch count
123
A/B repetition
124
A stitch length
125
B stitch length
126
A/B speed
030
thread tension A 1
010
stitch length 1
020
foot stroke 1
041
speed
027
automatic stroke switch
according to sewing speed
031
thread tension A 2
038
2
nd
tension level when
switched to 2
nd
stroke
039
release tension on
foot lift
150
thread trimming
153
trim stitch tension
158
trim stitches
159
trim stitch length
050
foot pressure
074
foot position on stop
077
needle position on stop
110
stitch in stitch
140
backtack or condensed
stitches at seam end
100
thread clamp
021
foot stroke 2
141
C stitch count
142
D stitch count
143
C/D repetition
144
C stitch length
145
D stitch length
146
C/D speed
028
automatic stroke switch
speed threshold
029
automatic stroke switch
delay
032
thread tension B 1
034
thread tension based
on material thickness
070
foot lift height
» SEWING PARAMETER
033
thread tension B 2
054
dynamic foot pressure
066
Edge guide hight
060
edge value
Содержание 5390
Страница 1: ...5390 INSTRUCTION MANUAL 07 2018 ...
Страница 2: ......
Страница 3: ...5390 INSTRUCTION BOOK 07 2018 ...
Страница 63: ...61 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 01 VETRON 8340 CONTROL BOX ...
Страница 64: ...62 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 02 POWER CONNECTION BLOCK DIAGRAM ...
Страница 65: ...63 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 03 8640 STEPPER DRIVER TERMINAL ...
Страница 66: ...64 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 04 8340 MAIN TERMINAL MAIN DRIVE ...
Страница 67: ...65 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 05 VETRON 5XXX HEAD PCB ...
Страница 68: ...66 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 06 VETRON 5XXX HEAD ADAPTER PCB ...
Страница 73: ...71 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 07 ERROR CODES 02 ERROR MESSAGES ...