69
07/2018
VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
ERROR CODE
DESCRIPTION
SOLUTION
» STEPPING MOTOR ERROR
200
Stroke encoder
»
Check connector and cable S1
»
Replace motor
»
Replace control box
203
Stroke motor overcurrent
»
Check connector and cable S1
»
Measure resistance of the coils
»
Replace motor
»
Replace control box
204
Stroke motor could not reach designated position
»
Check if the stitch regulator can move easily
»
Redo stroke zero wizard
205, 206, 207, 209
Stroke encoder EEPROM init error
»
Check connector and cable S1
»
Replace motor
»
Replace control box
210
Stepper driver BC Init error
Apply latest software update. If a timeout during
update occurs, replace control box
220
Stroke encoder timeout
Contact VETRON Support
290
Stepper driver BC software incompatible
Apply latest software update
300
Stitch length encoder
»
Check connector and cable S2
»
Replace motor
»
Replace control box
303
Stitch length motor overcurrent
»
Check connector and cable S2
»
Measure the resistance of the coils
»
Replace motor
»
Replace control box
304
Stitch length motor could not reach destinated
position
»
Check if the stitch regulator can move easily
»
Redo stitch length zero wizard
305, 306, 307, 309
Stitch length encoder EEPROM Init error
»
Check connector and cable S2
»
Replace motor
»
Replace control box
399
Stitch length and stroke connector interchanged
Check if S1 and S2 are pluged in correctly.
Swap if wrong
403
TensionB / Steppermotor - Post bed / Edge guide
height - X-Y overcurrent
»
Check connector and cable S3
»
Measure resistance of the coils
»
Replace motor
»
Replace control box
404
TensionB / Steppermotor - Post bed / Edge guide
height - X-Y guide not connected
410
Stepper driver DE Init error
Apply latest software update. If a timeout during
update occurs, replace control box
414
Post bed switch / Edge guide height Y-X guide
endposition not reached
»
Check connector and cable of the end switch
»
Check if the end position can be reached manually
»
Measure end switch function
424
Post bed switch / Edge guide height Y-X guide
endposition Switch
not connected or motor is blocked in Init position
490
Stepper driver DE software incompatible
Apply latest software update
07. ERROR CODES
02.
ERROR MESSAGES
-2-3
Содержание 5390
Страница 1: ...5390 INSTRUCTION MANUAL 07 2018 ...
Страница 2: ......
Страница 3: ...5390 INSTRUCTION BOOK 07 2018 ...
Страница 63: ...61 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 01 VETRON 8340 CONTROL BOX ...
Страница 64: ...62 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 02 POWER CONNECTION BLOCK DIAGRAM ...
Страница 65: ...63 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 03 8640 STEPPER DRIVER TERMINAL ...
Страница 66: ...64 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 04 8340 MAIN TERMINAL MAIN DRIVE ...
Страница 67: ...65 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 05 VETRON 5XXX HEAD PCB ...
Страница 68: ...66 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 06 VETRON 5XXX HEAD ADAPTER PCB ...
Страница 73: ...71 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 07 ERROR CODES 02 ERROR MESSAGES ...