68
07/2018
VETRON 5390 - POST BED MACHINE - INSTRUCTION BOOK
07. ERROR CODES
02.
ERROR MESSAGES
-1-3
ERROR CODE
DESCRIPTION
SOLUTION
» BUS ERROR
2
AC voltage is too high
Check supply voltage
3
AC voltage is too low
4
Bus voltage is too high
5
Bus voltage is too low
6
Discharge function error
Replace control box
7
Bus current too high
Apply main drive overload condition procedure
8
Bus voltage faulty
Replace control box
9
31V Overcurrent
»
Check all 31V consumers and cables (Bobbin
winder, thread clamp, trimmer, pneumatic
value) for short circuit
»
Replace control box
10
Command bus hard fault
»
Check cable and connector B1
»
Replace control box
60
Right bobbin monitor not connected
Check connection of bobbin thread monitor (Y1-A1)
61
Left bobbin monitor not connected
Check connection of bobbin thread monitor (Y1-A2)
» SAFETY ERROR
0
Obstacle detected
»
Clear area under the foot.
»
Avoid obstacles while foot is lowering
1
Timeout reading foot height
Contact VETRON Support
5
Timeout on foot height correction
10
Distance magnet / sensor too high
99
Critical safety module error
» MAIN DRIVE ERROR
100
Main motor encoder error
»
Check connector and cable M2
»
Replace main drive
»
Replace control box
101
Main drive current zero sample
»
Do not turn the machine with hand
after power on
»
Replace control box
103
Main drive overload
Apply main drive overload condition procedure
104
Main drive hold position overload
Disable hold torque, check if turning the machine
with the mechanical handwheel is smooth while
machine is initialized
105
Main drive current sample
Replace control box
NOTE:
The error codes refer to the control box connections. Depending on the machine type and
optional accessories, different functions can be controlled. This has to be considered
during troubleshooting.
Содержание 5390
Страница 1: ...5390 INSTRUCTION MANUAL 07 2018 ...
Страница 2: ......
Страница 3: ...5390 INSTRUCTION BOOK 07 2018 ...
Страница 63: ...61 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 01 VETRON 8340 CONTROL BOX ...
Страница 64: ...62 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 02 POWER CONNECTION BLOCK DIAGRAM ...
Страница 65: ...63 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 03 8640 STEPPER DRIVER TERMINAL ...
Страница 66: ...64 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 04 8340 MAIN TERMINAL MAIN DRIVE ...
Страница 67: ...65 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 05 VETRON 5XXX HEAD PCB ...
Страница 68: ...66 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 06 WIRING DIAGRAM 06 VETRON 5XXX HEAD ADAPTER PCB ...
Страница 73: ...71 07 2018 VETRON 5390 POST BED MACHINE INSTRUCTION BOOK 07 ERROR CODES 02 ERROR MESSAGES ...