Note:
If the up time is programmed before sunrise, the roller shutter moves 

up at sunrise.

If the up time is programmed after sunrise, the roller shutter moves 

up at the programmed up time.

If the down time is programmed after sunset, the roller shutter moves 

down at sunset.

If the down time is programmed before sunset, the roller shutter moves 

down at the programmed down time.

- 55 -

G

 

IMPORTANT!

  Activating the Astro  function automatically dis ables the 

week function.

x

Astro function 

Special functions

Activating the Astro function and setting the current calendar week 

will be performed in one programming step.

First press the set button and keep it pressed. Then press the day 

button twice.

The display will indicate

the following: 

(ßßßß0ß1A

Now set the current calendar week by pressing the day button.

Keep pressing the set button. Each additional pressing of the day 

 button will move to the next calendar week.

After you have set the current calendar week and released both but-

tons, the Astro function will be activated. The display will now switch 

to the current time. The display will continue to indicate the (A) in the 

upper right hand corner.

Keep the set button pressed and press the day button until the dis-

play indicates “ 

0ß0 

” in order to deactivate the Astro function.

- 56 -

G

Special functions 

Astro function

 

NOTE!

  In order to obtain optimum performance of the Astro func-

tion, the geographical location of your residence must be set 

by means of the DIP switches (see tables on page 58 and 59).

v

Содержание Rolltec Plus G/S

Страница 1: ...tely The control system should only be used for the purpose specified by the manufacturer refer to the operating instructions Any changes or modifications thereof are not permissible and will result i...

Страница 2: ...urope page 59 Reverse function page 60 Example for DIP switch setting page 61 41 G Contents G S functions General page 62 Functional description broken glass sensor page 63 Functional description sun...

Страница 3: ...time and day button simul ta ne ously to stop the quick run 43 G General Introduction The control features a selector switch with which manual mode H or automatic mode A can be selected Push the sele...

Страница 4: ...ushing the selector switch to manual mode H the auto matic mode can be interrupted for an extended period of time After selecting automatic mode again the control will execute the last pending command...

Страница 5: ...isplay and the time will be changed by one hour 47 G Summer winter time Basic functions By operating the combination of set and time button you can set the current time Setting the time can be perform...

Страница 6: ...nation of set and up button you can set the up time Setting the up time can be performed as follows 1 Press the set button first and keep it pressed then A Press the up button and keep it pressed to f...

Страница 7: ...G Down time Basic functions The random generator generates the so called random time which causes the roller shutters to move up or down with a deviation of 15 min utes to the previously programmed t...

Страница 8: ...ons The Astro function is basically an electronical calendar De pend ing on the stored sunrise and sunset times the up or down times are automatically corrected under consideration of the geo graphi c...

Страница 9: ...it pressed Then press the day button twice The display will indicate the following 0 1A Now set the current calendar week by pressing the day button Keep pressing the set button Each additional press...

Страница 10: ...no delay ON down command 30 minutes delayed Astro function Run time correction Special functions G 58 DIP 2 DIP 3 DIP 4 DIP 5 Area OFF OFF OFF OFF Schleswig Holstein Northern Lower Saxony OFF OFF OFF...

Страница 11: ...for airing purposes or to let pets go outside The reverse time can be set with DIP switches 7 and 8 and will only be executed at the programmed day week and sunrise sunset times during automatic opera...

Страница 12: ...DIP switch S6 see page 57 for S7 and S8 see page 60 The respective DIP switches are located on the rear panel of the control 61 G Example for DIP switch setting Special functions Your control feature...

Страница 13: ...ux sensor is exposed to sun rays the sun symbol will flash in the display After the sensor measures 1 minute of continuous sun shine the roller shutter moves as far down to cover the lux sensor In ord...

Страница 14: ...ntensity approx 22 kLux Sun response delay 1 minute Sun reset delay 16 minutes Setting the response sun intensity G S functions The roller shutter does not move up and down automatically Is the power...

Страница 15: ...nal injury or property damage Therefore When connecting the device observe the currently valid VDE standards in particular DIN VDE 0100 0700 your local power company s regulations and the current acci...

Страница 16: ...os f 0 8 ind Align switching time 120 seconds Software class A Operating temperature 0 C 32 F to 40 C 104 F IP class IP 40 Degree of contamination 2 Dimensions L W H 69 69 54 mm Colour information sig...

Страница 17: ...and ensure that it is located perpendicular with the cable going off to the bottom please refer to the picture on page 71 5 Plug the lux sensor jack into the left hand socket of the roller shutter co...

Страница 18: ...the time and day button simultaneously for 3 seconds this will make the time run 60 times faster That way you can check the entire func tional sequence within a short amount of time Example of a test...

Страница 19: ...D G Anschlussbild Wiring diagram Rolltec Plus G S D G bersicht Bedienungselemente Overview operating elements Rolltec Plus G S...

Страница 20: ...sich ber R ck gabe m g lich keiten in Ihrem Gebiet und nutzen Sie zur Entsorgung das R ck gabe system The disposal of electrical equipment and batteries in house hold waste is strictly forbidden The s...