G
The additional function “broken glass sensor” requires an extra
broken glass sensor for each control
(for larger or separated window
panes). The installation of the lux sensor is described below.
1. Push the selector switch all the way to the right until it clicks to set
the manual mode to (H).
2. Mix binder and hardener of the two-component adhesive thor-
oughly in a 1 : 1 ratio.
- 71 -
Broken glass sensor
Installation
3. Apply the adhesive to the side of the broken glass sensor that is
marked with a black bar.
4. Place broken glass sensor carefully onto to the window pane and
make sure to clear the window frame by minimum 2 inches. Attach
the broken glass sensor with adhesive tape and ensure that it
is located perpendicular with the cable going off to the bottom
(please refer to the picture on page 71).
5. Plug the lux sensor jack into the left-hand socket of the roller
shutter control.
6. Push the selector switch all the way to the left until it clicks to set
the automatic mode to (A).
7. Validity check:
Take a coin and tap the broken glass sensor with it in order to
simulate breaking glass. The roller shutter will now move down and
the display will indicate the broken glass symbol. Press the up button
to stop the roller shutter and delete the broken glass signal.
Remove the adhesive tape after the adhesive has hardened. Please
check the processing and hardening times for the use of the adhe sive
with the instructions on the adhesive packaging.
- 72 -
G
Installation
Broken glass sensor
IMPORTANT!
Make sure to keep the adhesive areas clean and oil-free.
x