G
The additional function “sun protection” requires an extra lux sensor
for each control
.
The installation of the lux sensor is described below.
1. Plug the lux sensor jack into the right-hand socket of the roller
shutter control.
2. Attach the lux sensor in the desired area of the window.
3. Push the selector switch all the way to the left until it clicks to set
the automatic mode to (A).
- 73 -
Lux sensor
Installation
After completing the installation, activate the quick run function in
order to check the additional function “sun protection” by pressing the
time and day button simultaneously for 3 seconds (this will make the
time run 60 times faster). That way you can check the entire func tional
sequence within a short amount of time.
Example of a test run:
1. Check whether you are within the range of the programmed up and
down times.
2. Press the time and day button simultaneously for 3 seconds.
3. Expose the lux sensor to light until the sun symbol flashes.
After approx. 1 second the shutter moves to the shade position.
Remove the light source.
The sun symbol in the display will flash again.
After 16 seconds, the roller shutter will move up again.
4. Press the time and day button shortly after the test run is com-
pleted.
5. Set the current time as described on page 48.
- 74 -
G
Installation
Lux sensor