Connecting the Gas Supply 23
5. Loosen the screws indicated in the figure below and connect a
manometer to the pressure port Reset the manometer to zero
.
before use.
Digital pressure
manometer
6. Re open the manual gas valve and check for leaks
-
.
7. Open multiple fixtures that have high flow rates such as
,
bathtub and shower faucets to ramp the boiler up to its
,
maximum firing rate.
8. When the boiler reaches its maximum firing rate check the
,
inlet gas pressure reading on the manometer The gas pressure
.
must fall within the ranges specified on page 8.
To measure the inlet gas pressure:
1. Shut off the manual gas valve on the gas supply line.
2. Open a hot water faucet The boiler should turn on and the gas
.
in the gas supply line will be purged.
3. Leave the faucet on until the boiler shuts down due to a lack of
gas supply and then turn off the hot water faucet
,
.
4. Remove the front cover by loosening the 2 Phillips head screws
securing it to the case.
CAUTION
Ensure that no cables are in the way before folding down the
PCB assembly If the assembly is stuck do not force it Doing
.
,
.
so may damage the cables and result in serious malfunctions.
Check again to ensure that no cables or any other parts are in
the way before you proceed.
Opened
Closed
WARNING
●
The boiler cannot function without sufficient inlet gas pressure.
Measuring the inlet gas pressure should be performed by a
licensed professional only.
●
The inlet gas pressure must be maintained between 3.5 in and
10.5 in W.C for natural gas and between 8.0 in and 13.5 in W.C
propane.
The appliance and its individual shutoff valve must be disconncted
from the gas supply piping system during any pressure testing of
●
The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressure equal to
●
that system at test pressure in excess of 1/2psi(3.5 kPa).
or less than ½ psi(3.5kPa).
4.2
Measuring the Inlet Gas Pressure
Содержание VC 100 (LP) COMBI
Страница 11: ...1 5 Dimensions VC 100 COMBI About the Boiler 11 ...
Страница 12: ...VC 120 140 COMBI 12 About the Boiler ...
Страница 40: ...10 2 Component Assembly Diagrams and Parts Lists VC 100 COMBI 10 2 1 Case Assembly 40 Appendixes ...
Страница 41: ...Appendixes 41 10 2 2 Burner Assembly 204 220 221 ...
Страница 42: ...10 2 3 Waterway Assembly 303 345 306 307 308 340 342 341 343 344 345 343 341 305 42 Appendixes ...
Страница 45: ...10 3 Component Assembly Diagrams and Parts Lists VC 120 140 COMBI 10 3 1 Case Assembly Appendixes 45 ...
Страница 46: ...10 3 2 urner Assembly B 46 Appendixes ...
Страница 47: ...Appendixes 47 10 3 3 Assembly Water Line 347 348 349 353 350 351 338 319 347 348 349 353 35 35 3 3 ...