Maintenance
Electrode Wire Needle Cleaning/Replacement
After using long hours, dust adhered around the electrode wires. Dust adhesion can lower the
performance of ionizing. Periodically clean or replace the electrode wires.
1) Before cleaning the electrode wires, shut OFF power and unplug the power supply adapter from
the electrical outlet. Also, lay the electrode wires on a cloth or mat not to damage while cleaning.
2) Turn the needle electrode unit to the left and remove it.
Be careful not to stick yourself on the wires.
3) Install the Electrode needle unit.
4) Attach the protection cover to F12E-E and connect the AC adapter.
Make sure the front cover is securely installed.
If the cover is not installed correctly, the safety mechanism will operate causing the fan to stop.
CAUTION
CLEANING
If the discharge needle is dirty, it could lower the static erasing performance or
cause dust to fly around. Be sure to clean the contaminated parts according to
your service condition.
When replacing the discharge needle
If the static erasing performance does not recover even after cleaning, the discharge needle could be worn out.
Remove the discharge needle the same as for cleaning and replace it with a new one.
Accessories
Electrode Needle Plate:F-12EH
WARNING
PROHIBITED
If the knob of the electrode needle unit is broken or dropped out, stop the
operation and replace it with a new one. It can lead to an electric shock or
injury.