Operation
POWER
This is used to start and stop the unit.
When switched to [
―
], the power is turned on, the switch
LED lights up, and operation starts.
When switched to [
○
], the power is turned off and operation
stops.
FAN SPEED
Step-less adjustment is used to adjust the fan speed.
Use a thin flathead screwdriver to make the adjustment.
The rotation range is 270 degrees. Forcing the screw any
further may result the unit to damage.
ALARM LAMPS
H.V.ALARM
(
High voltage alarm lamp
)
If the piezoelectric transformer detects an overload and
shuts down the operation, the high-voltage alarm lamp will
light up.
When any of the alarm lamps lights,
1)
Unplug the power cable.
2)
Remove the fan cover and visually inspect around the
discharge needles.
If debris is adhered to the needles, refer to Cleaning
Procedure and clean the needles.
FAN ALARM
Fan lock alarm lamp lights when the fan motor stops rotating.
When fan lock alarm lamp lights,
1)
Unplug the power cable.
2)
Remove the fan cover and visually inspect around the fan.
If debris is adhered to the fan, remove the debris and switch on the power again and make
sure that the lamp is off.
※
If the alarm lamp comes on again, contact the supplier for servicing.