background image

„

 Maintenance

 

 

 CAUTIONS

 

IN MAINTENANCE AND CHECKS

 

 

DO NOT 

DISASSEMBLE

 

Do not disassemble F12E-E. Servicing is reserved for service engineers.

 

 

UNPLUG 

POWER CABLE

 

Before making checks, unplug the power cable. Working with the power 
on can result in electric shock and breakdown. 

 

PROHIBITED 

Do not wipe F12E-E with detergent or solvent. It may cause cracking and 
result in electric shock or breakdown. 

 

DO NOT WET

 

Do not wet F12E-E. Contact with moisture can result in electric shock or 
breakdown. 

 

CHECK

 

Periodically check F12E-E. Failure of periodical inspection can result in 
early breakdown. 

 

Casing Cleaning 

To clean the casing, wipe with a dry soft cloth. Suck up dust from openings with a vacuum cleaner. 

 

 CAUTION

 

   

PROHIBITED

 

Do not wipe it with solvents or cleaners, such as alcohol or paint thinner. 
It may cause cracking and result in electric shock or breakdown. 

 

 

DO NOT WET

 

Do not wet F12E-E. Contact with moisture can result in electric shock or 
breakdown.

 

 

When cleaning the front cover 

After using for long hours, dust adhered to the front cover may lower the ionizing performance or 
cause dust to fly around. 
Care for periodical cleaning. 

)Be sure to turn the power switch to 

  to stop the operation. 

)Unplug the power supply adapter from the electrical outlet.

 

)Remove the fixture securing the upper surface cover

 

)Wipe it with a dry, soft cloth. 

)Reinstall the front cover. 

 

 CAUTION

 

   

CLEANING 

A dirty front cover could lower the static erasing performance or cause dust 
to fly around. Be sure to clean it as required by the operation environment. 

 
 
 
 

10 

Содержание STAT-CLEAN F12E-E

Страница 1: ...struction manual before use Keep it in a safe handy place for future reference Table of Contents For Your Safety P 2 Product Features P 3 Production Specifications P 4 External View P 5 Performance P 6 Installation P 7 Before Use P 8 Operation P 9 Maintenance P 10 Troubleshooting P 13 Storage P 14 ...

Страница 2: ...n proofing F12E E is not of explosion proof construction therefore explosion or fire may occur PROHIBITED Do not use F12E E in flammable atmospheres The corona discharge can act as an ignition source and cause an explosion or fire PROHIBITED Do not use F12E E in environments subjected to sharp temperature fluctuations or dewing This kind of environment can lead to breakdown DO NOT WET Do not use F...

Страница 3: ...pacity coupling is used to charge electrode wires with high voltage in order to maintain good ion balance No adjustment required High precision ion balancing within 5V DESIGNED FOR SAFETY To prevent electrical shock the circuit is cut off and the power turned off when the front guard is opened Less Ozone Due to Dischange Design of efficient Ion output extremely less Ozon is generated Monitor funct...

Страница 4: ...t cut off when open Working ambient temperature humidity 5 40 35 65 RH No dewing Distance from target area 150 900mm Installation location Non dangerous indoor location Static electricity removal time Refer to the items in the capabilities chart Ion balance Within 5V At 300mm Air filter Pre filter Material Casing Steel with coated finish Stand Stainless Front Cover ABS Electrode Inconel Accessorie...

Страница 5: ... External View No F12E E No AD 24 IT 5 ...

Страница 6: ...mperature 25 Humidity 50 Top row Ion Balance value Middle row Attenuation time from 1000 V to 100 V Bottom row Attenuation time from 1000 V to 100 V At max fan speed The values above were based on tests with a sample unit They represent the central tendency of this model but they are not guaranteed 6 ...

Страница 7: ...s etc Where strong electric or magnetic fields are generated When Used on a Desktop F12E E can be used on the desktop Do not locate on unstable tables etc F12E E can be damaged and malfunctioned if it falls When Mounted on a Wall or Structure Select a location and height in consideration of F12E E s static electricity removal range For information regarding the static electricity removal range ref...

Страница 8: ...m sources of heat PROHIBITED Do not test the electrode wires for grounding short circuiting or sparking These tests can adversely affect ion balance Connector connection Insert the included special AC adapter connector into the jack on the back of the body Power Supply Adapter Use the power adapter AD24 IT which is specifically designed for use of F12E E The AC adapter plug is a 3 pronged plug Con...

Страница 9: ...sformer detects an overload and shuts down the operation the high voltage alarm lamp will light up When any of the alarm lamps lights 1 Unplug the power cable 2 Remove the fan cover and visually inspect around the discharge needles If debris is adhered to the needles refer to Cleaning Procedure and clean the needles FAN ALARM Fan lock alarm lamp lights when the fan motor stops rotating When fan lo...

Страница 10: ...ings with a vacuum cleaner CAUTION PROHIBITED Do not wipe it with solvents or cleaners such as alcohol or paint thinner It may cause cracking and result in electric shock or breakdown DO NOT WET Do not wet F12E E Contact with moisture can result in electric shock or breakdown When cleaning the front cover After using for long hours dust adhered to the front cover may lower the ionizing performance...

Страница 11: ...e AC adapter Make sure the front cover is securely installed If the cover is not installed correctly the safety mechanism will operate causing the fan to stop CAUTION CLEANING If the discharge needle is dirty it could lower the static erasing performance or cause dust to fly around Be sure to clean the contaminated parts according to your service condition When replacing the discharge needle If th...

Страница 12: ...ile still wet could damage the unit 3 Dust will also be adhered to the outside and inside filter covers so use a dry soft cloth to wipe them off 4 Reinstall the filter and reinstall the filter cover CAUTION CLEANING If the filter is dirty it could lower the static erasing performance or cause dust to fly around Be sure to clean the contaminated parts according to your service condition When replac...

Страница 13: ... in the following situations It may result in fire or electric shock When F12E E has been damaged because of dropping or shock When air is not blowing though the power switch of the eraser is in the ON position When the power cable is damaged or hot When the power supply adapter is loosely connected to the electrical outlet UNPLUG POWER CABLE If trouble occurs with F12E E turn the power switch OFF...

Страница 14: ...ange noises or vibrates during use If sparks are seen coming from electrode wire tips In normal operation sparks are not seen CAUTION STORAGE PROHIBITED Do not store F12E E in the following places Adverse environments can cause product breakdown Where exposed to vibrations or shock Where temperature and humidity are outside specified ranges Where dewing occurs Where temperature fluctuates sharply ...

Страница 15: ...15 ...

Страница 16: ...lect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract ...

Отзывы: