background image

Vertiv

| Liebert

®

 EXM

 MBC Installation Manual  |   

i

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1.0

MECHANICAL INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.2

Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.3

Environmental Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.3.1

Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.3.2

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.4

Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.4.1

Moving the Cabinets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.4.2

Clearances  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.4.3

Floor Installation/Anchoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.5

Cable Entry  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.6

Power Cables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.6.1

Power Cable Connection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.0

INSTALLATION DRAWINGS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3.0

SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

3.1

Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

3.2

Torque Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

FIGURES

Figure 1

Cabinet arrangement—Liebert EXM UPS, battery cabinets, maintenance bypass cab-
inet6

Figure 2 One-line diagram, single-input Liebert EXM 10-40kVA UPS with three-breaker Lieb-

ert EXM
MBC and input/output transformer cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Figure 3 One-line diagram, single-input Liebert EXM 10-200kVA UPS with three-breaker Lieb-

ert
EXM MBC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Figure 4 One-line diagram, dual-input Liebert EXM 10-100kVA with two-breaker Liebert MBC

12

Figure 5 One-line diagram, dual-input Liebert EXM 10-100kVA UPS with four-breaker Liebert 

EXM MBC
and input isolation transformer cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Figure 6 One-line diagram, dual-input Liebert EXM 10-200kVA UPS with three-breaker Lieb-

ert
EXM MBC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Figure 7 One-line diagram, dual input Liebert EXM 10-200kVA with four-breaker Liebert MBC

15

Figure 8 Bend radius—Neutral and ground wires through bottom feed, 10-40kVA system . . 15
Figure 9 Main components—200mm Liebert EXM MBC, two to four breakers, 10-40kVA sys-

tem16

Содержание Liebert EXM MBC

Страница 1: ...Liebert EXM MBC User Manual 10 200kVA 208 120V and 220 127V 60Hz...

Страница 2: ...r damages resulting from use of this information or for any errors or omissions Refer to other local practices or building codes as applicable for the correct methods tools and materials to be used in...

Страница 3: ...net6 Figure 2 One line diagram single input Liebert EXM 10 40kVA UPS with three breaker Lieb ert EXM MBC and input output transformer cabinet 10 Figure 3 One line diagram single input Liebert EXM 10 2...

Страница 4: ...23 Terminal details 800mm Liebert EXM MBC three breakers 160 200kVA system29 Figure 24 Terminal details 800mm Liebert EXM MBC four breakers 160 200kVA system 30 Figure 25 Control wiring diagram Lieber...

Страница 5: ...UPS with internal batteries 36 Table 15 Liebert EXM MBC input currents single input main 37 Table 16 Liebert EXM MBC input currents dual input rectifier 38 Table 17 Liebert EXM MBC input currents dual...

Страница 6: ...Vertiv Liebert EXM MBC Installation Manual iv...

Страница 7: ...ware that the system contains high DC as well as AC voltages Check for voltage with both AC and DC voltmeters prior to making contact AVERTISSEMENT Le centre de gravit lev des appareils pr sente un ri...

Страница 8: ...y test equipment designed for troubleshooting should be used This is particularly true for oscilloscopes Always check with an AC and DC voltmeter to ensure safety before making contact or using tools...

Страница 9: ...t tre utilis s Cette mise en garde couvre notamment les oscilloscopes Utilisez toujours un voltm tre c a et c c pour v rifier les tensions avant d tablir un contact ou d utiliser des appareils Des ten...

Страница 10: ...ately Verify that the correct equipment is being installed The equipment supplied has an identification tag on the back of the main door reporting the type size and main calibration parameters of the...

Страница 11: ...ons bars auxiliary terminal blocks and power isolators 1 4 1 Moving the Cabinets The route to be travelled between the point of arrival and the unit s position must be planned to make sure that all pa...

Страница 12: ...ed to the cabinets they are connected to The cable design must comply with the voltages and currents provided in Tables 15 through 17 follow local wiring practices and take into consideration the envi...

Страница 13: ...for heavy currents as a way of easing installation WARNING Risk of electric shock Can cause equipment damage injury and death Before cabling up the cabinet ensure that you are aware of the location an...

Страница 14: ...ship attached to the UPS The 600mm and 800mm maintenance bypass cabinets ship separately from the UPS Liebert EXM UPS Liebert EXM UPS Maintenance Bypass Cabinet Matching Battery Cabinet Matching Liebe...

Страница 15: ...m me la mort Le non respect des proc dures de mise la terre peut entra ner des risques d lectrocution du personnel ou des risques d incendie en cas de d fectuosit de la mise la terre WARNING Risk of...

Страница 16: ...a single input type connect the AC input supply cables between the Liebert EXM MBC and the UPS bypass input supply busbars A B C or A B C N terminals and connect AC jumper connectors between UPS bypas...

Страница 17: ...he UPS to the main ground system must follow the most direct route possible Consideration should be given to the use of smaller paralleled cables for heavy currents as a way to ease installation In mo...

Страница 18: ...TERY NOTES 1 Install in accordance with national and local electrical codes 2 Input and bypass must share the same single source 3 Bypass and rectifier inputs and output cables must be run in separate...

Страница 19: ...single source 3 A neutral is required from the system AC input source Vertiv recommends a full capacity neutral conductor and grounding conductors 4 Bypass and rectifier inputs and output cables must...

Страница 20: ...s must share the same single source 3 A neutral is required from the system AC input source Vertiv recommends a full capacity neutral conductor and grounding conductors 4 Bypass and rectifier inputs a...

Страница 21: ...al codes 2 Vertiv recommends a full capacity neutral conductor and grounding conductors 3 Bypass and rectifier inputs and output cables must be run in separate conduits 4 Control wiring must be run in...

Страница 22: ...single source 3 A neutral is required from the system AC input source Vertiv recommends a full capacity neutral conductor and grounding conductors 4 Bypass and rectifier inputs and output cables must...

Страница 23: ...AC input source Vertiv recommends a full capacity neutral conductor and grounding conductors 4 Bypass and rectifier inputs and output cables must be run in separate conduits 5 Control wiring must be...

Страница 24: ...ker Configuration Configured Breaker 2 MBB MIB 3 BIB MBB MIB 4 RIB BIB MBB MIB Table 3 Terminal block details 200mm Liebert EXM MBC two to four breakers 10 40kVA system Terminal Block Single Input Sys...

Страница 25: ...ration Configured Breaker 2 MBB MIB 3 BIB MBB MIB 4 RIB BIB MBB MIB Table 5 Terminal block details 300mm Liebert EXM MBC two to four breakers 60 100kVA system Terminal Block Single Input System Dual I...

Страница 26: ...2 Main components 600mm Liebert EXM MBC three to four breakers 120 160kVA system RIGHT SIDE VIEW Panel Removed LEFT SIDE VIEW Panel Removed FRONT VIEW Door Removed Neutral Busbar MBB MIB EXM15104 RIGH...

Страница 27: ...0mm Liebert EXM MBC three or four breakers 160 200kVA system RIGHT SIDE VIEW Panel Removed LEFT SIDE VIEW with Panel Removed 160 180kVA Models LEFT SIDE VIEW Panel Removed 200kVA Model Only FRONT VIEW...

Страница 28: ...for forklift handling 5 Control wiring and power wring must be run in separate conduits 6 All wiring must be in accordance with national and local electrical codes 7 Liebert EXM MBC will always be att...

Страница 29: ...s of vertical 4 Top and bottom cable entry available through removable access plates Remove punch to suit conduit size and replace 5 Unit bottom is structurally adequate for forklift handling 6 Contro...

Страница 30: ...r forklift handling 5 Control wiring must be run in separate conduits 6 All wiring is to be in accordance with national and local electrical codes 7 The maintenance bypass cabinet will always be attac...

Страница 31: ...ly adequate for forklift handling 5 Control wiring must be run in separate conduits 6 All wiring is to be in accordance with national and local electrical codes 7 The maintenance bypass cabinet will a...

Страница 32: ...FRONT Door Not Shown RIGHT SIDE Panel Not Shown MIB BIB RIB Output TB3 See Detail A MBB NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring must be in accordance wit...

Страница 33: ...MBB MIB Neutral Busbar Input TB2 See Detail A Rectifier Input TB4 See Detail A Ground Busbar LEFT SIDE Panel Not Shown FRONT Door Not Shown RIGHT SIDE Panel Not Shown MIB BIB RIB Output TB3 See Detail...

Страница 34: ...nel Not Shown MIB See Detail B MBB Input See Detail A Ground Busbar See Detail A Neutral Busbar MBB See Detail B NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring m...

Страница 35: ...r See Detail A Neutral Busbar MBB See Detail B NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring must be in accordance with national and local electrical codes 3 If...

Страница 36: ...Ground Busbar See Detail A Neutral Busbar MBB See Detail B NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring must be in accordance with national and local electric...

Страница 37: ...e Detail A Ground Busbar See Detail A Neutral Busbar MBB See Detail B NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring must be in accordance with national and loca...

Страница 38: ...tail A Ground Busbar See Detail A Main Input Busbar See Detail A Neutral Busbar MBB See Detail B NOTES 1 Control wiring and power wiring must be run in separate conduits 2 All wiring must be in accord...

Страница 39: ...Customer furnished electrode conductor must be installed in accordance with national and local electrical codes 2 Overcurrent protection is based on 80 rated devices 3 MBB auxiliary switch connections...

Страница 40: ...tiv Liebert EXM MBC Installation Manual 34 Figure 26 Solenoid key release unit 200mm Liebert EXM MBC K0 K1 K2 TB1 Fuseblock for SKRU Solenoid key release unit is mounted between the BIB and MBB breake...

Страница 41: ...tiv Liebert EXM MBC Installation Manual 35 Figure 27 Solenoid key release unit 300mm Liebert EXM MBC K0 K1 K2 Solenoid key release unit is mounted between the BIB and MBB breakers TB1 Fuseblock for SK...

Страница 42: ...t EXM MBC Installation Manual 36 Figure 28 Solenoid key release unit 600mm Liebert EXM MBC Figure 29 Solenoid key release unit 800mm Liebert EXM MBC K0 K1 TB1 Fuseblock for SKRU K2 TB1 Fuseblock for S...

Страница 43: ...n mm 78 74 2000 Weight lb kg 198 90 288 131 535 243 700 318 Color Black ZP 7021 Degree of Protection for UPS Enclosure IP 20 with and without front door open Standards and Conformities UL1778 5th Edit...

Страница 44: ...0 100kVA and 300mm Liebert EXM MBC UPS Rating kVA UPS Weight lb kg Liebert EXM MBC 300mm Weight lb kg Combined Weight UPS and Liebert EXM MBC lb kg 60kVA 844 383 288 131 1132 514 80kVA 918 416 288 131...

Страница 45: ...uminu m Wire Bolt Size 208 120 220 127 10 34 3W N G 45 65 1 6 1 4 M10 208 120 220 127 15 51 3W N G 70 85 1 4 1 2 M10 208 120 220 127 20 68 3W N G 90 115 1 2 1 1 0 M10 208 120 220 127 30 102 3W N G 150...

Страница 46: ...220 127 20 68 90 3W N G 115 1 2 1 1 0 M10 208 120 220 127 30 102 150 3W N G 175 1 2 0 1 4 0 M10 208 120 220 127 40 136 175 3W N G 230 1 4 0 2 1 0 M10 208 120 220 127 60 205 300 3W N G 400 2 3 0 2 4 0...

Страница 47: ...220 127 20 56 70 3W N G 115 1 2 1 2 M10 208 120 220 127 30 83 110 3W N G 130 1 1 0 1 2 0 M10 208 120 220 127 40 111 150 3W N G 175 1 3 0 1 4 0 M10 208 120 220 127 60 167 225 3W N G 285 2 300 2 2 0 M10...

Страница 48: ...27 60 167 3W N G 225 285 2 300kcmil 2 2 0 M10 208 120 220 127 80 222 3W N G 300 400 2 3 0 2 4 0 M10 208 120 220 127 100 278 3W N G 350 460 2 4 0 2 300kcmil M10 208 120 220 127 120 333 3W N G 450 620 2...

Страница 49: ...256 030695 868 4AWG 256 030695 733 2 3AWG 54811BE 1AWG 54857BE 1 0AWG 256 30695 593 2 0AWG 54862BE 60238 3 0AWG 54864BE 60244 4 0AWG 54866BE 60250 250kcmil 54868BE 60256 300kcmil 54870BE 60262 350kcm...

Страница 50: ...Vertiv Liebert EXM MBC Installation Manual 44 NOTE Refer to the manufacturer s data for proper torque for circuit breaker power connections...

Страница 51: ...Vertiv Liebert EXM MBC Installation Manual 45 NOTES...

Страница 52: ...Vertiv Liebert EXM MBC Installation Manual 46...

Страница 53: ......

Страница 54: ...mes and logos referred to are trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracy and completeness herein Vertiv Co assu...

Отзывы: