8
vertilux.com
© 2019. Vertilux, Ltd. All Rights Reserved. Last revised: February 2019.
If you need to reset the tilting motor
Set DIP switch
No. 4
in the
ON
position.
Remove
GEARS 1
,
2
and
3
to release the chain
(fig. 3)
.
Follow the procedure described in either
Case #1
or
Case #2
depending on your situation.
These procedures apply for the traversing as well as the tilting motors.
Case #1:
Both motor buttons, the blue and the red one, do not “click” when pressed.
RED OR BLUE
BUTTON IS UNLOCKED
OPPOSITE DIRECTION
BUTTON
4.
Press and hold the button that is unlocked on
the motor until you complete step 5. On the wall
control, press the
button
in
the
opposite direction
to that selected in step 1 and allow the motor to
operate until it stops on its own.
RED OR BLUE
BUTTON IS
UNLOCKED
STOP
BUTTON
DIRECTION
BUTTON
1.
On the
wall control
, keep pressing either
direction button
until the motor stops on its own.
If the button you pressed does not start the
motor, or if after several minutes the motor does
not stop, try the opposite direction button.
Remember which
direction button
you selected in
this step.
2.
Press the
stop button
on the
wall control
.
3.
Test the
red
and
blue buttons
again. At this
point, one of them should be able to make a
"click" sound. That button is now unlocked.
Resetting the motor to factory default
If you need to reset the traversing motor
Set DIP switches
No. 2
and
No. 4
in the
ON
position.
Remove
GEAR 1
to release the chain. To do this, remove the track
COVER
and remove
GEAR 1 (fig. 3)
.
Follow the procedure described in either
Case #1
or
Case #2
depending on your situation.
These procedures apply for the traversing as well as the tilting motors.
Содержание VTi 6-710-VB-00110
Страница 20: ......