Other Items You will Need:

We have used several torches to anneal cases while developing your new machine. The

Clamps supplied with your annealer are manufactured slightly oversize to accept ½” diameter

nozzles. Any propane torch made by ‘Bernz-O-Matic’®, ‘Worthington’® and others should work

fine as long as they have ½” diameter nozzles.

(

NOTE: When placing the nozzles into the clamps, ensure that you do not cover up the

inlet holes at the base of the nozzle. This will make them burn lean and possibly

overheat the nozzles and Clamp Assemblies.)

What we have most often used is a pair of kits from ‘Bernz-O-Matic’®. The Torch Kit Part

Number is #UL100 and comes with one propane tank & one torch. Cost is about $11.00 per set

from your local hardware store. If you would like to purchase the torches separately, the Part

Number is #UL2317.

Aside from the torch units, we recommend using a temperature sensing liquid named

‘Tempilaq’®. It is made by Tempil® Corporation, South Plainfield N.J. We buy ours from

McMaster-Carr®. You can order via the internet,

http://www.mcmaster.com/#temperature-

indicators/=69wlzo

or by phone (609) 689-3415. Tempilaq® is also available from many

welding supply houses. (NOTE: Do not use the temperature crayons. The liquid is far superior

on cartridge cases.)

Also, please read all warnings and directions for use in the

Tempilaq

®

package.

While ordering, go ahead and purchase a bottle of thinner for the

Tempilaq®. A few drops of thinner will restore the solution to its original condition after it begins

to dry out and thicken over time.

When ordering, you will have to specify the temperatures you desire. We most often use 650

°

F

for sensing neck & shoulder temperatures and 350

°F or 400°F on the lower half of the case

body. Temperatures may vary according to the way you use your annealer, but these

will be good starting places. We will explain in detail how to apply the Tempilaq

®

to

sense the temperature while you are annealing in the SETUP SECTION.

Содержание 10G107

Страница 1: ...r revision without notice BENCH SOURCE ANNEALING MACHINE Model 10G107 VERTEX MANUFACTURING CORPORATION I Introduction II Cautions III What s in the Box What You Will Need IV Annealing Info and Why Ann...

Страница 2: ...50 CFM Fan Unit They will not heat up significantly during use No plastic to bow or warp Table acts as a heat sink to help maintain hardness in the cartridge case head 5 Index Plate is fixed and inde...

Страница 3: ...le substances in the vicinity of the annealer while it is being used 7 NEVER leave the area where your annealer is being used or while the torches are lit A phone call or other distraction could spell...

Страница 4: ...n shown on the OPERATOR PANEL just above the fuse holder This may lead to destruction of your power supply or worse yet cause harm to your power outlet 14 ALWAYS select a safe secure storage place to...

Страница 5: ...ed a Carrier Plate for indexing your cartridge cases Please see below Assembly 1 After removing the contents from the package please turn your annealing machine up side down and screw the 4 adjusting...

Страница 6: ...mmend using a temperature sensing liquid named Tempilaq It is made by Tempil Corporation South Plainfield N J We buy ours from McMaster Carr You can order via the internet http www mcmaster com temper...

Страница 7: ...manufacturer to another but 70 30 is the base line The reason this material is chosen is because it forms well is less expensive than other brass or bronze with a higher copper content and is well su...

Страница 8: ...have an infinite life Pay attention to things such as case stretch and overall length as well as the number of trimmings There are many reloading manuals available which explain dangerous situations a...

Страница 9: ...the round level mounted in the table of your machine This is for reference only The Table Top does not have to be perfectly level to prevent cartridge cases from tipping while indexing 2 Referring to...

Страница 10: ...that you may adjust the Timer anytime you wish The timing will change real time Note You must push the switch down to the Manual position while the spindle is rotating to stop the function of the mac...

Страница 11: ...okay but it is not usually necessary Please repeat these steps until your cartridge case type runs as described above Make sure the last operation of the Manual switch was to rotate the spindle Auto...

Страница 12: ...e temperature very closely The walls of these cases are very thin and the case heads will get too soft very quickly 13 Now we re ready to start annealing cases Place one setup cartridge case about 3 4...

Страница 13: ...take pictures of your setups while annealing We do that all the time when machining less common parts Always clean the exterior of your case necks and shoulders if they are smoked up with carbon from...

Страница 14: ...he owner The cost of repairs will be itemized in the estimate and must be prepaid along with return shipping costs prior to return shipment All return shipments will include insurance for the value of...

Страница 15: ...description of the malfunction you have experienced This will help us to better determine the problem you may be having Also we may be able to cure the problem over the phone After receipt of your un...

Страница 16: ...ine or any other products that we manufacture Whether it is to make recommendations comments share concerns or complain about quality or customer service we welcome you to share it with us BENCH SOURC...

Отзывы: