Next, operate the switch to the manual position and release. The Drive Plate will index to the

next position. After indexing, again actuate the switch to the down or ‘Manual’ position and hold

it long enough to check the run out of the cartridge. The spindle will rotate the case in the

counter-clockwise direction. When the case begins to spin, note whether it moves from left-to-

right or right-to-left.

If the cartridge moves from left-to-right, the Carrier Plate needs to be adjusted slightly

clockwise. If the cartridge moves from right-to-left, the Carrier Plate needs to be adjusted

slightly counter-clockwise. It will usually only take a small amount of movement of the Carrier

Plate to get it to place the cartridge case in the center of the spindle.

Our intent here is to get the cartridge case to fully rotate without hitting the Carrier Plate while

rotating. If you want to get the case to rotate dead true that is okay, but it is not usually

necessary.

Please repeat these steps until your cartridge case type runs as described above. Make sure

the last operation of the ‘Manual’ switch was to rotate the spindle.

(‘Auto’ Mode will not work

unless the last ‘Manual’ function rotates the spindle).

8. Next remove all of your cartridge cases from the Carrier Plate and install your Clamps and

Torches to your machine as shown. Please see below.

Then place a single cartridge case in the next upcoming station. Index the case by operating

the switch to the ‘Manual’ position. After indexing, adjust your torches to approximately pass

through the case center line while looking from above. Then looking from the side of the

machine, adjust your torches to where it appears that the flame will hit the case approximately

in the midpoint of the shoulder. Please try to keep the torch nozzles parallel to the Carrier Plate

to prevent it from getting any hotter than necessary. This is especially true if annealing shorter

cases.

When you are satisfied that your setup looks like the pictures shown, actuate the ‘Manual’

switch one more time to rotate the spindle and remove the cartridge case.

Содержание 10G107

Страница 1: ...r revision without notice BENCH SOURCE ANNEALING MACHINE Model 10G107 VERTEX MANUFACTURING CORPORATION I Introduction II Cautions III What s in the Box What You Will Need IV Annealing Info and Why Ann...

Страница 2: ...50 CFM Fan Unit They will not heat up significantly during use No plastic to bow or warp Table acts as a heat sink to help maintain hardness in the cartridge case head 5 Index Plate is fixed and inde...

Страница 3: ...le substances in the vicinity of the annealer while it is being used 7 NEVER leave the area where your annealer is being used or while the torches are lit A phone call or other distraction could spell...

Страница 4: ...n shown on the OPERATOR PANEL just above the fuse holder This may lead to destruction of your power supply or worse yet cause harm to your power outlet 14 ALWAYS select a safe secure storage place to...

Страница 5: ...ed a Carrier Plate for indexing your cartridge cases Please see below Assembly 1 After removing the contents from the package please turn your annealing machine up side down and screw the 4 adjusting...

Страница 6: ...mmend using a temperature sensing liquid named Tempilaq It is made by Tempil Corporation South Plainfield N J We buy ours from McMaster Carr You can order via the internet http www mcmaster com temper...

Страница 7: ...manufacturer to another but 70 30 is the base line The reason this material is chosen is because it forms well is less expensive than other brass or bronze with a higher copper content and is well su...

Страница 8: ...have an infinite life Pay attention to things such as case stretch and overall length as well as the number of trimmings There are many reloading manuals available which explain dangerous situations a...

Страница 9: ...the round level mounted in the table of your machine This is for reference only The Table Top does not have to be perfectly level to prevent cartridge cases from tipping while indexing 2 Referring to...

Страница 10: ...that you may adjust the Timer anytime you wish The timing will change real time Note You must push the switch down to the Manual position while the spindle is rotating to stop the function of the mac...

Страница 11: ...okay but it is not usually necessary Please repeat these steps until your cartridge case type runs as described above Make sure the last operation of the Manual switch was to rotate the spindle Auto...

Страница 12: ...e temperature very closely The walls of these cases are very thin and the case heads will get too soft very quickly 13 Now we re ready to start annealing cases Place one setup cartridge case about 3 4...

Страница 13: ...take pictures of your setups while annealing We do that all the time when machining less common parts Always clean the exterior of your case necks and shoulders if they are smoked up with carbon from...

Страница 14: ...he owner The cost of repairs will be itemized in the estimate and must be prepaid along with return shipping costs prior to return shipment All return shipments will include insurance for the value of...

Страница 15: ...description of the malfunction you have experienced This will help us to better determine the problem you may be having Also we may be able to cure the problem over the phone After receipt of your un...

Страница 16: ...ine or any other products that we manufacture Whether it is to make recommendations comments share concerns or complain about quality or customer service we welcome you to share it with us BENCH SOURC...

Отзывы: