background image

 

122051C VERSATILE DEEP CLEANER 115V 

Legend Brands, Inc. 

 

FIRE HAZARD 

Do not use to pick up flammable or combustible liquids, 

such as gasoline, or use in areas where these liquids 

may be present. 
Do not pick up any type of hazardous dust or toxic 

materials, including burning or smoking cigarettes, 

matches, or hot ashes. 

 

 

Use only as described in this manual. Use only 

manufacturer’s recommended cleaning solutions and 

accessory tools. 
Excess foam can damage machine components. Add 

defoamer to the recovery tank per instructions if needed. 
To unplug, grasp the plug, not the cord. Do not pull cord 

to unplug. Do not pull or carry by cord, close a door or 

window on cord, or pull cord around sharp edges or 

corners. Do not roll appliance over cord. Keep cord away 

from heated surfaces. 
Do not wheel machine up or down stairs. 
Do not put any object into openings. Do not use with any 

opening blocked; keep free of dust, lint, hair and 

anything that may reduce airflow. 
Do not use machine if not in proper operating condition. 
Protect from freezing. Freezing may damage internal 

components and will void warranty. 
Do not use with water with over 3 grains per gallon (51 

milligrams per liter) of hardness. Use with hard water 

could result in the formation of mineral deposits inside 

pumps and fittings. Damage caused by mineral deposits 

will void warranty. Inquire with your local water utility 

about water hardness, or have your water tested.  
Use only to extract moisture. Do not immerse end of 

vacuum hose in liquid. 
Do not use as a dry vacuum. Dust particles will damage 

the vacuum motors. Damage caused by dry vacuuming 

will void the warranty. 
To prevent the growth of mold and mildew inside the 

tanks, always drain waste tank after use. 
Do not modify machine from its original design. All 

repairs must be performed by a qualified service 

technician using only parts approved by Legend Brands.

 

GROUNDING INSTRUCTIONS  

WARNING! Improper connection of the 

equipment-grounding conductor can result in 

a risk of electric shock. Check with a qualified 

electrician or service person if you are in doubt as to 

whether the outlets are properly grounded. Do not 

modify the plugs provided with the appliance—if the 

plugs do not fit the outlets, have proper outlets 

installed by a qualified electrician.  

This equipment is for use on a circuit or circuits having a 

nominal rating no more than 120V and is factory-

equipped with a specific electric cord and plug to permit 

connection to a proper electric circuit. Make sure that the 

appliance is connected to outlets having the same 

configuration as the plugs. No adaptor should be used 

with this appliance. If the appliance must be reconnected 

for use on a different type of electric circuit, the 

reconnection should be made by qualified service 

personnel. 

CONTROLS  

ON THE CONTROL PANEL (Fig. 2) 

Includes two rocker-type switches to control the blower 

and the heater/solution pump.  

SETUP 

1.  Press release button to extend handle.  
2.  Release twist latch, slide recovery tank forward and 

lift up. Set tank aside.  

3. 

Cleaning:

 Add cleaning solution to water in bucket to 

make 2 gallons total (max.) and pour into solution 

tank.  

4. 

Plain water rinsing:

 Add 2 gallons (max.) of plain 

water to solution tank.  

NOTICE

: Use a low-foam detergent to control foaming in 

the vacuum system and keep moisture, carpet fiber and 

other debris from being drawn through the vacuum cutoff 

valve and causing damage to the vacuum motors. 

Damage caused by moisture or debris will void the 

product warranty. Foaming may also occur because of 

residues left from previous cleanings. If this happens, 

use a defoamer additive. We recommend the use of 

Chemspec Crystal Defoamer (part no. 104177). Follow 

defoamer manufacturer instructions for proper use. 

5.  Connect both hoses.  
6.  Plug into grounded outlet.  

 

D

 

 

C

 

 

Fig. 2: Control Panel 

 

 

Blower ON/OFF 

 

Solution pressure pump and 

heater ON/OFF 

Содержание 108779

Страница 1: ...aged cord or plug If appliance is not working as it should has been dropped or damaged return it to an authorized service center for repair Do not leave machine unattended when plugged in Unplug cord...

Страница 2: ...ian using only parts approved by Legend Brands GROUNDING INSTRUCTIONS WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified ele...

Страница 3: ...ng Possibility of electrical shock WARNING Interior components may be hot after operation Let unit cool completely before servicing DAILY OR AFTER EACH USE Rinse solution tank with clear water to ensu...

Страница 4: ...e si se ha ca do o da ado devu lvalo a un centro de servicio autorizado para su reparaci n No deje la m quina sin atenci n cuando est enchufada Desenchufe el cable del tomacorriente cuando no est en u...

Страница 5: ...a aspiradora en l quido No use como aspiradora en seco Las part culas de polvo da ar n los motores de la aspiradora El da o causado por la aspiraci n en seco anular la garant a Para prevenir el crecim...

Страница 6: ...la manguera de la aspiradora a n colocada levante la aspiradora verticalmente para drenar el agua en la manguera hacia el tanque de recuperaci n c Retire la manguera de la aspiradora del tanque de re...

Страница 7: ...ac o 4 5 pulg 114 3 mm Hg Presi n de pulverizaci n de la soluci n 58 PSI 400 kPa Flujo de pulverizaci n de la soluci n 0 18 GPM 0 68 LPM Dimensiones Alto Prof Ancho 22 4 26 0 11 1 pulg 56 9 66 0 28 2...

Страница 8: ...pas utiliser avec un adaptateur Ne pas utiliser avec des rallonges Ne pas utiliser avec un cordon ou une fiche endommag s Si l appareil ne fonctionne pas comme il le devrait s il est tomb ou a t endo...

Страница 9: ...ion avec de l eau dure pourrait entra ner la formation de d p ts min raux l int rieur des pompes et des raccords Les dommages caus s par des d p ts min raux annuleront la garantie Renseignez vous aupr...

Страница 10: ...commencez le nettoyage voir NETTOYAGE ci dessus Vider remplir les r servoirs AVIS Lorsque la solution de nettoyage est puis e 1 videz le r servoir de r cup ration et 2 remplissez le r servoir de solu...

Страница 11: ...s com VDC CleanerLivingProducts com CARACT RISTIQUES Mod le 108779 Capacit R servoir de solution 2 5 gal 9 5 L R servoir de r cup ration 2 0 gal 7 6 L Port e de l aspirateur 4 5 po 114 3 mm Hg Pressio...

Отзывы: