![Versa Flame BY12-084-029-97 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/versa-flame/by12-084-029-97/by12-084-029-97_assembly-and-operating-instructions_1006670006.webp)
BY12-084-029-97 Eng P. 6 20111105-V0
WARNING
Keep the fuel supply hose away from any heated surfaces.
WARNING
z
The pressure regulator and hose assembly supplied with your gas grill must be
used. Replacement pressure regulators and hose assemblies must be those
specified by the grill manufacturer.
z
Do not attempt to connect it to any other fuel supply source.
z
Do not attempt to adjust or repair the regulator. The regulator is designed to operate
at the maximum output pressure of 11 inches of water column (2.74 kPa).
CONNECTION PROCEDURES
Connecting Regulator to the LP Tank
1. Place LP tank on a secure, level, and stable surface.
2. Turn control knob to the OFF position.
3. Turn LP tank OFF by turning OPD hand wheel clockwise to a
full stop
.
4. Remove the protective cap from the LP
tank valve. Always use dust cap and
strap supplied with valve.
5. Hold regulator, insert nipple (B) into LP
tank valve. Hand tighten coupling nut,
holding regulator in a straight line (C)
with LP tank valve so as not to cross
thread the connection.
6. Turn the coupling nut clockwise to tighten to a full solid stop. The regulator will seal on
the back-check feature in the LP tank valve, resulting in some resistance. An additional
one-half to three quarters turn is required to complete connection. Tighten by hand
only – do not use tools.
NOTE: If you cannot complete connection, disconnect regulator and repeat step 5 and 6. If
you are still unable to complete the connection,
do not use this regulator!
To disconnect LP gas cylinder:
WARNING
z
If the grill is not in use, the gas must be turned off at the supply cylinder(s). Storage of
the grill is permissible only if the cylinder is disconnected and removed from the grill.
z
Cylinders must be stored outdoors out of the reach of children and pets and must not
be stored in a building, garage or any other enclosed area.
Do not use a POL transport plug (A)
(plastic part with external threads)! It
will defeat the safety feature of the
valve.
Содержание BY12-084-029-97
Страница 25: ...BY12 084 029 97 Eng P 25 20111105 V0 Step 3 Step 4 D 2 3 D D D D E E 8 D 4...
Страница 26: ...BY12 084 029 97 Eng P 26 20111105 V0 Step 5 Step 6 D 6 9 A 10 A 12 11...
Страница 27: ...BY12 084 029 97 Eng P 27 20111105 V0 Step 7 Step 8 18 D 44...
Страница 29: ...BY12 084 029 97 Eng P 29 20111105 V0 Step 12 Step 13 24 VALVE 24 E L 35 D...
Страница 30: ...BY12 084 029 97 Eng P 30 20111105 V0 Step 14 Step 15 M 32 31 H M 29 J D 30 H 38 H C...
Страница 31: ...BY12 084 029 97 Eng P 31 20111105 V0 Step 16 Step 17 39 G 39...
Страница 33: ...BY12 084 029 97 Eng P 33 20111105 V0 2 Step 20 Step 21 D 15 15 D 15 D 1 Left Back Left Front...
Страница 34: ...BY12 084 029 97 Eng P 34 20111105 V0 Step 22 Step 23 D 16 D 16 16 D 1 2 Right Back Right Front...
Страница 35: ...BY12 084 029 97 Eng P 35 20111105 V0 Step 24 Step 25 19 G SIDE BURNER VALVE F...
Страница 36: ...BY12 084 029 97 Eng P 36 20111105 V0 Step 26 Step 27 46 B F 40 J...
Страница 37: ...BY12 084 029 97 Eng P 37 20111105 V0 Step 28 Step 29 Q R 34 B 41 35 L D 47 41 D H P 47 14 13 Q...
Страница 38: ...BY12 084 029 97 Eng P 38 20111105 V0 Step 30 Tighten all the bolts and nut in step 27 Step 31 Step 32 43 E 42 7...
Страница 39: ...BY12 084 029 97 Eng P 39 20111105 V0 Step 33 Step 34 45 25 33...
Страница 40: ...BY12 084 029 97 Eng P 40 20111105 V0 Step 35 Step 36 48 28 27 26 50...
Страница 43: ...BY12 084 029 97 Eng P 43 20111105 V0...