Any  conversion  required  must  be  performed  by  your  dealer  or  a  qualified 

licensed technician or gas service company. Please provide the service person 

with this manual before work is started on the range. (Gas conversions are the 

responsibility of the dealer or end user.)

d.  This range can be used with NATURAL or LP/PROPANE gas. It is shipped from 

the factory adjusted for use with NATURAL gas.

e.  Manifold pressure should be checked with a manometer and by operating as 

below detailed:

• 

Remove the injector from the rear left (or rear right) burner and mount the 

proper test point adapter which is available from the After-Sales Service 

(see side figure and the “

OPERATIONS TO BE PERFORMED WHEN 

SUBSTITUTING  THE INJECTORS OF THE COOKTOP BURNERS” 

chapter).

• 

Turn the rear left (or rear right) burner control knob to the maximum position.

• 

Press the knob and keeping it pressed check the manifold pressure with a 

manometer; NATURAL gas requires 4.0” W.C.P. and LP/PROPANE requires 

11.0” W.C.P.

• 

Incoming line pressure upstream from the regulator must be 1” W.C.P. 

higher than the manifold pressure in order to check the regulator.

• 

The regulator used on this range can withstand a maximum input pressure 

of 1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a 

stepdown regulator will be required.

f.  The appliance, its individual shut-off valve, and pressure regulator must be 

disconnected from the gas supply piping system during any pressure testing of 

that system at pressures in excess of 1/2 PSI (3.5 kPa).

g.  The appliance must be isolated from the gas supply piping system by closing its 

individual manual shut-off valve during any pressure testing of the gas supply 

piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).

3. Flexible Connections:

If local codes permit, CSA or UL design-certified, flexible metal appliance connector is 

recommended for connecting this range to the gas supply line. Do Not kink or damage 

the flexible connector when moving the range. The pressure regulator has 1/2” NPT 

female pipe threads.You will need to determine the fittings required, depending on the 

size of your gas supply line, flexible metal connector and shutoff valve.

4. Rigid Pipe Connections:

If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to 

obtain an in-line connection to the range. All strains must be removed from the supply 

and fuel lines so range will be level and in line.
• 

Use joint compounds and gaskets that are resistant to action of natural or 

propane gas on all male pipe threads.

• 

Do  not  over  tighten  gas  fitting  when  attaching  to  pressure  regulator.  Over 

tightening may crack regulator.

5. Leak Testing:

IMPORTANT: Leak testing of the appliance shall be conducted as follows:
• 

After  final  gas  connection  is  made,  turn  on  manual  gas  valve  and  test  all 

connections in gas supply piping and appliance for gas leaks with a soapy water 

solution. During this test all appliance gas valves have to be closed.

• 

In order to avoid property damage or serious personal injury, never use a Iighted 

match. If a leak is present, tighten joint or unscrew, apply more joint compound, 

tighten again and retest connection for leak.

Fig. 2.7

TEST POINT ADAPTER

The Test Point adapter is available from the 

After-Sales Service.

2

Содержание VDFSGG365 Series

Страница 1: ...ACTURED MOBILE HOME The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safe...

Страница 2: ...followed exactly a fire or explosion may result causing property damage personal injury or death WARNING WARNING Slide range back so bolt head on the adjustable bracket assembly is under anti tip brac...

Страница 3: ...ommercial or communal environment CONVERSION LABEL DATA PLATE The product data plate is attached below the bottom drawer To check the label it is necessary to remove the drawer see Setting the pressur...

Страница 4: ...THE APPLIANCE IMPORTANT The use of suitable protective clothing gloves is recommended when handling or installing this appliance WARNING THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER Inst...

Страница 5: ...r other codes or in the absence of such codes with the Standard for Recreational Park Trailers ANSI A119 5 4 To eliminate risk of burns or fire by reaching over heated surface units cabinet storage lo...

Страница 6: ...ve the countertop for a width of minimum 36 911 mm it has to be centered with the range Side wall cabinets above the range must be a minimum of 18 457 mm above the countertop 4 Air curtain or other ov...

Страница 7: ...lacing the 7 8 backguard with the 3 backguard assemble it by using the same screws spacers used for fixing the 7 8 backguard figs 1 3a 1 3b GAS AND ELECTRIC CONNECTION Fig 1 2 Dotted line showing the...

Страница 8: ...mum H 0 0 A C A B G E D F A A B G E D F C OVEN VENT OVEN VENT H H Maximum height of cabinetry immediately adjacent to the range from floor to countertop Depending on the height of the feet adjustment...

Страница 9: ...6 Fig 1 6 LEVELLING THE COOKER The cooker may be levelled by screwing the lower ends of the feet IN or OUT fig 1 7 It is important to observe the directions of figure 1 7 1 31 32 50 mm 0 mm 0 Fig 1 7...

Страница 10: ...p bracket and ensure they are properly fitted together to prevent the range from tipping To fit the anti tip bracket 1 Thread the bolt through the adjustable bracket and fix in place using the two sup...

Страница 11: ...two nuts are well tightened after any adjustments IMPORTANT Use the proper screws to fix the stability bracket in place according to the type of material on the floor and or wall Before drilling and h...

Страница 12: ...nt guard as shown in figure 1 12 1 Remove the backguard A 2 Remove the pan supports the burner caps and the flame spreaders 3 Unscrew cooktop fixing screws B and C in figure below 4 Remove the cooktop...

Страница 13: ...so can result in death explosion or fire Fig 2 1 All gas connections must be made according to national and local codes This gas supply service line must be the same size or greater than the inlet lin...

Страница 14: ...the extension pipe interposing the gasket supplied The regulator cover must be oriented toward the front side of the range IMPORTANT use two wrenches to tighten the connection Insert the extension pi...

Страница 15: ...front side of the range IMPORTANT use two spanners to tighten the connection STEP 4 Fix the extension pipe support bracket onto the back of the range using the two supplied screws Take care to ensure...

Страница 16: ...ing Gasket Range manifold Manifold male pipe fitting 1 2 G cylindrical ISO 228 1 male E x t e n s i o n p i p e f e m a l e p i p e f i t t i n g 1 2 G cylindrical ISO 228 1 female Gasket Extension pi...

Страница 17: ...be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 PS...

Страница 18: ...ing to the INJECTORS TABLE The nozzle diameters expressed in hundredths of a millimetre are marked on the body of each injector CAUTION Save the injectors removed from the appliance for future use SET...

Страница 19: ...y the safety catches will automatically hook into place Fig 2 10 Pressure regulator REGULATOR COVER NATURAL GAS REGULATION LP PROPANE REGULATION Fig 2 9 To set the pressure regulator fig 2 9 1 Unscrew...

Страница 20: ...ation of the primary air 2 INJECTORS TABLE NOMINAL POWER REDUCED POWER LP PROPANE 11 W C P NATURAL GAS 4 W C P BURNERS BTU hr BTU hr injector 1 100 mm injector 1 100 mm Semirapid SR 8000 1500 85 139 T...

Страница 21: ...adjustment is correct Inside crown of DUAL burner Light the DUAL burner Set the gas valve to position minimum rate of inner crown Remove the knob With a thin screwdriver turn the regulation screw R2 u...

Страница 22: ...5 Withdraw the burner as shown in figure 2 16 Using a 7 mm box spanner unscrew the injector indicated by the arrow in fig 2 16 and replace it with a new one selected in accordance with the Injectors t...

Страница 23: ...shown in figure 2 18 Using a 7 mm box spanner unscrew the injector indicated by the arrow in fig 2 18 and replace it with a new one selected in accordance with the Injectors table Then replace the bu...

Страница 24: ...you obtain a flame of 3 4 mm in height The flame should not go out even when passing suddenly from maximum to minimum flame N B For LP PROPANE gas the by pass screw must be fixed thoroughly Afterregu...

Страница 25: ...installed must be electrically grounded in accordance with local codes Recommended ground method For your personal safety this range must be grounded This range is equipped with a 3 prong ground plug...

Страница 26: ...molimitateur de s curit PA Cooktop burners ignition switches group Groupe d interrupteurs d allumage br leurs de la table de travail A Oven broil ignition coil G n rateur d allumage four gril A1 Cookt...

Страница 27: ...27...

Страница 28: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...

Отзывы: