20
OPERATIONS TO BE PERFORMED WHEN
SUBSTITUTING THE INJECTORS OF THE
COOKTOP BURNERS
•
Remove the pan supports, the burner caps and the flame
spreaders.
•
Using a wrench substitute the nozzle injectors “
J
1
”, “
J
2
”,
“
J
3
” and “
J
4
” (figs. 2.11, 2.12, 2.13) with those most suitable
for the kind of gas for which it is to be used.
•
Refit the flame spreaders, the burner caps and the pan
supports.
The burners are conceived in such a way so as not to require
the regulation of the primary air.
2
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
BURNERS
BTU/hr
BTU/hr
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Semirapid (SR)
8000
1500
85
139
Triple-ring (TR)
12000
5000
102
170
Dual (D)
Inner crown
2800 (1)
1100 (1)
50 (3)
80 (3)
Outer crown
17000 (2)
6500 (2)
80 (x2) (4)
139 (x2) (4)
Oven burner
17000
3200
120
208
Broil burner
13000
-
105
184
(1) Power calculated only with inner crown operating
(2) Power calculated with inner and outer crown operating
(3) inner crown (“
J
3
” in figure 2.13)
(4) outer crown (“
J
4
” in figure 2.13)
J
2
J
3
J
4
Fig. 2.12
Fig. 2.13
J
1
Fig. 2.11
SEMI-RAPID BURNER
DUAL BURNER
TRIPLE-RING BURNER
Содержание VDFSGG365 Series