DVA4136 Series Direct Vent Gas Fireplace
10010270
Conversion to LP
Minimum
Burner Orifice
Input (BTU/hr)
Kit #
Model
Rate Screw
Front
Part #
Rear
Part #
Minimum Maximum
10010369
DVA4136IN
#51
#61
57622
#52
50996
7,100
38,000
10010519
(.039”)
(.0635”)
Conversion to Natural Gas
Minimum
Burner Orifice
Input (BTU/hr)
Kit #
Model
Rate Scew
Front
Part #
Rear
Part #
Minimum Maximum
10010371
DVA4136IP
LSS-00
#52
50996
#36
10002896
7,100
38,000
20012264
(.0635”)
(.1065”)
Table 1 Injector Orifice Size Matrix
Table 2 Air Shutter Setting
Conversion
Front
Rear
From
To
Natural Gas
LP
1/2” Open
Fully Open
LP
Natural Gas
1/4” Open
Round Hole 1/2 Open