DVA4136 Series Direct Vent Gas Fireplace

10010270

Remote Control Transmitter Operation Matrix

Set Temperature:

  This will ONLY appear when the  

 

THERMOSTAT is activated

Manual ON:

 

When manual ON, the word ON  

 

will appear and when manual OFF  

 

the word OFF will appear.

Program Mode:

 

This P1 and P2 for weekdays  

 

and weekends icon will appear  

 

when the program is operational 

Thermostat Range:

 

The range for the room   

 

temperature readout is 32-99° F.   

 

The room temperature always  

 

displays on the LCD. 

 

The range for set temperature is  

 

45- 99° F.  It is factory set at 45°F.  

 

The users will have to use UP/ 

 

DOWN buttons to set their desired  

 

set temperature.

Flame Icon:

 

The flame-1 icon will be ON all the  

 

time the main or the rear burner  

 

flame is ON, whether it is under  

 

Manual ON, THERMOSTAT or  

 

PROGRAM modes.

The installation of the transmitter batteries, 2 "AAA", will 
activate the initial set up of the system. Setup mode can 
also be activated at any time by pressing the FLAME 
REAR and PROG/TIME buttons simultaneously for 5 
seconds. The control will automatically exit setup mode 
if no button is pressed within 20 seconds.
This system will allow the temperature unit conversion, 
gas type conversion, and clock set up while in Setup 
mode per the following setup procedure.

Setting of C/F conversion:

 

•  C/F conversion: Use UP or DOWN key to choose 

Celsius or Fahrenheit, Press "SET" button to 
continue to gas type setup.

Gas Type Conversion:

 

•  NG/LP conversion: Use UP or DOWN key to choose 

Natural Gas or Liquid Propane, Press "SET" button 
to continue to clock set up.

Clock Setup: 

•  Use UP or DOWN key to set "Hour", then press SET 

to enter “Minute” setting.

•  Use UP or DOWN key to set “Minute”, and then 

press SET to enter "AM/PM" setting.

•  Use UP or DOWN key to set "AM/PM", the press 

SET to enter "Day of Week" setting.

•  Use UP of DOWN key to select the "Day of the 

Week".

Manual Mode

Push MODE button for manual ON, the flame ICON 
will come on the LCD screen. The second push of the 
MODE button will put the control into the THERMO 
mode. You can continue to push the MODE one more 
time to OFF.

NOTE:  The MODE button will operate ON - 
THERMO - OFF in a series that will cycle from ON to 
THERMO to OFF.
Fan Mode

The control of the fan will be from a button on the 
handheld transmitter.  When the FAN button is pressed, 
the FAN setting level will flash on the LCD display and 
the user can select desired setting from highest to 
lowest with 6 different levels to the fan motor via the UP 
and DOWN buttons.  If no adjustment is made within 7 
seconds, the control will exit the function setting mode 
and the LCD display will return to the normal view.
Delayed ON/OFF – The fan output will be energized 5 
minutes after the main flame is turned on and will be 
turned off 12 after the main flame is turned off.  This 
applies to both manual and thermal mode.  If the main 
flame is turned off and then cycled back on within the 
12 minute off-delay period, the fan should remain on 
(the 5-minute ON delay is omitted in this condition).

Lighting Mode

The control of the lighting output will be from a button 
on the handheld transmitter.  When the LIGHT button is 
pressed, the LIGHT setting level will flash on the LCD 
display and the user can select desired setting from 
highest to lowest with 6 different levels to the lighting 
output via the UP and DOWN buttons.  If no adjustment 
is made within 7 seconds, the control will exit the 
function setting mode and the LCD display will return to 
the normal view.
The lights are completely independent of the main 
flame coming ON and OFF.  The user can turn the 
lighting output ON or OFF regardless of the state of the 
main flame and changing the state of the main flame 
will have no effect on the lighting output.

Continuous Pilot

Operation of this feature of having the pilot to run all the 
time will be activated with the pressing of two buttons, 
"PROG/TIME" & "FLAME 1". This action will activate 
the Icon on the LCD screen. Pressing of the same two 
buttons will de-activate the feature.
This feature is the same as the standard AF-4000 
module, but activation of the system is different in that 
two buttons must be depressed to activate or de-
activate the function.  This feature can also be activated 
via a 2-position switch on the side of the main module.

Содержание TrimWorks DVA4136

Страница 1: ...w the gas suppliers instructions If you cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING P...

Страница 2: ...Applications Installations 18 Venting Components 20 Operating Instructions Glass Information 21 Louvre Removal 21 Window Frame Assembly Removal 21 Glass Cleaning 22 Installation of Logs Lava Rock Emb...

Страница 3: ...lace DVA4136 Certi ed To ANSI Z21 88b 2008 CSA 2 33b 2008 Vented Gas Fireplace Heaters 12 This replace requires adequate ventilation and combustion air to operate properly 13 This replace must not be...

Страница 4: ...ent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB...

Страница 5: ...1162 mm 3 2 8 2 2 m m 5 8 1 6 m m 6 4 1 6 4 5 m m 20 524 mm 20 524 mm 7 191 mm 22 575 mm 7 178 mm Dia 4 102 mm Dia 5 8 16 mm 2 51 mm 6 168 mm 6 152 mm 24 610 mm 6 152 mm 1 25 mm 40 1016 mm 36 914 mm 4...

Страница 6: ...s and legs may be installed at any height and width around the appliance When using paint or lacquer to nish the mantel such paint or lacquer must be heat resistant to prevent discoloration Clearance...

Страница 7: ...t and secure it rmly in place Gas Speci cations Max Min Gas Input Input Model Fuel Control BTU h BTU h DVA4136IFN Natural Gas 6 Volt Hi Lo 38 000 7 100 DVA4136IFP Propane 6 Volt Hi Lo 38 000 7 100 Gas...

Страница 8: ...stalled must be elec trically connected and grounded in accord ance with local codes or in the absence of local codes with the current CSA C22 1 Canadian Electrical Code For USA installations follow l...

Страница 9: ...tor To Pilot Ignitor To Pilot Flame Sensor Battery Back Up Pack Red Black Learn Button Remote Off Switch Continuous Pilot ON OFF Switch Optional ON OFF Switch Step Motor Main Flame Orange Brown Red Ye...

Страница 10: ...m General Venting There must not be any obstruction such as bushes garden sheds fences decks or utility buildings within 24 610 mm from the front of the termination hood Do not locate termination hood...

Страница 11: ...tlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW...

Страница 12: ...High Temperature Sealant Hose Clamp FP1471 Fig 10 Apply high temperature sealant to 4 and 7 pipes Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combust...

Страница 13: ...e vent ange Sidewall vent graph showing the relationship between vertical and horizontal dimensions for a Direct Vent ue system Vertical dimension from the oor of the replace to the center of the hori...

Страница 14: ...siding It is always best to locate the replace in such a way that minimizes the number of offsets and horizontal vent length of vent pipe from the ue collar of the replace to the face of the outer wal...

Страница 15: ...op with 8 sheet metal screws supplied Install restop assembly Fig 19 Zero clearance sleeve is only required for combustible walls STEP 3 Place replace into position Fig 20 Measure the ver tical height...

Страница 16: ...127mm 6 172mm FP1474 spacer springs 4 04 djt 4 Flex Vent Pipe Spacer Spring FP1474 Fig 24 Install spacer springs STEP 6 Use appropriate length of pipe sections telescopic or xed and install the horizo...

Страница 17: ...e to the wall 7 Level the soil to maintain a 4 102 mm clearance below snorkel Fig 26 Do not back ll around snorkel A clearance of at least 4 102 mm must be maintained between snorkel and the soil If t...

Страница 18: ...of vent pipe can be used between elbows Fig 29 7DVCS must be used to support offsets Fig 31 This application will require that you rst determine the roof pitch and use the appropriate starter kit Refe...

Страница 19: ...f there is a room above ceiling level restop spacer must be installed on both the bottom and the top side of the ceiling joists If an attic is above ceiling level a 7DVAIS Attic Insulation Shield must...

Страница 20: ...l Venting for 7TDVSKV A order 1 12 to 6 12 roof pitch for 7TDVSKV B order 7 12 to 12 12 roof pitch for 7TDVSKV F order at roof Starter Kit for Below Grade Installation Model 7TDVSKS Snorkel Kit Twist...

Страница 21: ...down to allow access 1 Turn the replace OFF including the pilot 2 If the unit has been operating allow time for the components to cool 3 If the unit has the standard louvre accessory follow the Louvr...

Страница 22: ...denti cation Chart Logs Part ID Rear Log 10010261 M1 Front Log 10010262 M2 Left Log 10010263 M3 Top Center Log 10010264 M4 Top Right Log 10010265 M5 Top Front Log 10010266 M6 It is necessary to period...

Страница 23: ...he log over the front left locator pin on the burner Fig 37 Place the left side of the log just inside the stop bracket on the left of the burner Fig 37 Front Log M2 LG512 Figure 40 4 Place the front...

Страница 24: ...bottom of the log over the pins on the front log The top of the log will rest against the rear log Fig 41 6 Place the top right log M5 Place the bottom rectangular sot of this log onto the right side...

Страница 25: ...25 DVA4136 Series Direct Vent Gas Fireplace 10010270 Figure 44 LG515...

Страница 26: ...OFF position FP297A Warning If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury and loss of life Lighting Instructions Turning Off the...

Страница 27: ...o push the MODE one more time to OFF NOTE The MODE button will operate ON THERMO OFF in a series that will cycle from ON to THERMO to OFF Fan Mode The control of the fan will be from a button on the h...

Страница 28: ...e control will accept the 10 minute setting exit the function setting mode and the LCD display will return to the normal view Pushing TIMER button you can set the ashing clock with the TIMER under the...

Страница 29: ...l ash Use UP or DOWN to change the setting of P2 ON Use SET button to enter into next setting S S on LCD will ash Use UP or DOWN to change the setting of P2 OFF Push OK button to enter into next setti...

Страница 30: ...ton is being pressed The LED indicator should illuminate on wall transmitters and on off hand held transmitters Buttons should be pressed and held for 1 to 2 seconds to ensure a complete signal is sen...

Страница 31: ...rely connected to the terminal labeled S on the control module Fig 45 Make sure the orange and white leads from the module are securely connected to the terminals labeled PILOT on the valve body Fig 4...

Страница 32: ...d red leads from the battery pack or the AF4000 110H L module are securely connected to the red and black leads from the motor drive or H L latching solenoid located on the valve body red to red and b...

Страница 33: ...n gasket with mixer tube mounting plate 6 Reassemble into the replace the burner housing assembly the burner tube assembly and the fettle in reverse order Mixer Tube Replacement Conversion to NG ONLY...

Страница 34: ...mixer tube supplied with conversion kit using screw from old mixer tube Refer to Table 2 to set shutter opening 4 Using 2 screws install new mixer tube and new spring assembly into burner housing asse...

Страница 35: ...7 100 38 000 10010519 039 0635 Conversion to Natural Gas Minimum Burner Ori ce Input BTU hr Kit Model Rate Scew Front Part Rear Part Minimum Maximum 10010371 DVA4136IP LSS 00 52 50996 36 10002896 7 1...

Страница 36: ...ide 2 Let replace cool if it has been running 3 Remove window frame assembly Refer to Window Frame Assembly Removal section 4 Remove logs 5 Vacuum burner compartment especially around ori ce primary a...

Страница 37: ...56 8 Remove the glass noting the orientation of the gas ket on the glass Fig 57 9 Remove the bad bulb s and install new bulb s Fig 58 10 Reassemble the replace in reverse order Light bulb replacement...

Страница 38: ...n design materials speci cations prices and discontinue colors and products at any time with out notice DVA4136 Units GFYN5J0 2 3 4 8 15 18a b 30 40 36 41 10270 DVA4136 parts 10 07 5 43 14 13 37 27 1a...

Страница 39: ...t not shown 10002896 16b Or ce Rear Burner 51 067 LP not shown 57598 17a Ori ce Front Burner 52 0635 Nat not shown 50996 17b Ori ce Front Burner 59 041 LP not shown 57177 18a Ori ce Pilot Nat 10002268...

Страница 40: ...Flue Pipe 10002237 39 Burner Tray Gasket 20012346 40 Relief Plate Assembly Burner Base 10004192 41 Plate Relief w Gasket Assembly 10002429 42 Shield Heat Pilot 10010144 43 24 Wire Harness 8 Pin 8 Wire...

Страница 41: ...onic fan speed control box on bottom of replace base lining up mounting holes with screw studs Fasten fan speed control box with 10 24 hex nuts Option B The speed control can be installed in an electr...

Страница 42: ...replace Kit Color DV4136CRSS Sandstone DV4136CRR Colonial Red DV4136CRG Silver Grey DV4136CRB Classic Black DV4136CRCG Country Grey Ceramic Refractory Panels Take care when handling the refractory pa...

Страница 43: ...shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions o...

Страница 44: ...cy Ratings Model EnerGuide Ratings Steady State D O E Fireplace Ef ciency Fan ON AFUE DVA4136IFN 70 81 68 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corpo...

Отзывы: