DVA4136 Series Direct Vent Gas Fireplace
10010270
Remote Control Transmitter Operation Matrix
Set Temperature:
This will ONLY appear when the
THERMOSTAT is activated
Manual ON:
When manual ON, the word ON
will appear and when manual OFF
the word OFF will appear.
Program Mode:
This P1 and P2 for weekdays
and weekends icon will appear
when the program is operational
Thermostat Range:
The range for the room
temperature readout is 32-99° F.
The room temperature always
displays on the LCD.
The range for set temperature is
45- 99° F. It is factory set at 45°F.
The users will have to use UP/
DOWN buttons to set their desired
set temperature.
Flame Icon:
The flame-1 icon will be ON all the
time the main or the rear burner
flame is ON, whether it is under
Manual ON, THERMOSTAT or
PROGRAM modes.
The installation of the transmitter batteries, 2 "AAA", will
activate the initial set up of the system. Setup mode can
also be activated at any time by pressing the FLAME
REAR and PROG/TIME buttons simultaneously for 5
seconds. The control will automatically exit setup mode
if no button is pressed within 20 seconds.
This system will allow the temperature unit conversion,
gas type conversion, and clock set up while in Setup
mode per the following setup procedure.
Setting of C/F conversion:
• C/F conversion: Use UP or DOWN key to choose
Celsius or Fahrenheit, Press "SET" button to
continue to gas type setup.
Gas Type Conversion:
• NG/LP conversion: Use UP or DOWN key to choose
Natural Gas or Liquid Propane, Press "SET" button
to continue to clock set up.
Clock Setup:
• Use UP or DOWN key to set "Hour", then press SET
to enter “Minute” setting.
• Use UP or DOWN key to set “Minute”, and then
press SET to enter "AM/PM" setting.
• Use UP or DOWN key to set "AM/PM", the press
SET to enter "Day of Week" setting.
• Use UP of DOWN key to select the "Day of the
Week".
Manual Mode
Push MODE button for manual ON, the flame ICON
will come on the LCD screen. The second push of the
MODE button will put the control into the THERMO
mode. You can continue to push the MODE one more
time to OFF.
NOTE: The MODE button will operate ON -
THERMO - OFF in a series that will cycle from ON to
THERMO to OFF.
Fan Mode
The control of the fan will be from a button on the
handheld transmitter. When the FAN button is pressed,
the FAN setting level will flash on the LCD display and
the user can select desired setting from highest to
lowest with 6 different levels to the fan motor via the UP
and DOWN buttons. If no adjustment is made within 7
seconds, the control will exit the function setting mode
and the LCD display will return to the normal view.
Delayed ON/OFF – The fan output will be energized 5
minutes after the main flame is turned on and will be
turned off 12 after the main flame is turned off. This
applies to both manual and thermal mode. If the main
flame is turned off and then cycled back on within the
12 minute off-delay period, the fan should remain on
(the 5-minute ON delay is omitted in this condition).
Lighting Mode
The control of the lighting output will be from a button
on the handheld transmitter. When the LIGHT button is
pressed, the LIGHT setting level will flash on the LCD
display and the user can select desired setting from
highest to lowest with 6 different levels to the lighting
output via the UP and DOWN buttons. If no adjustment
is made within 7 seconds, the control will exit the
function setting mode and the LCD display will return to
the normal view.
The lights are completely independent of the main
flame coming ON and OFF. The user can turn the
lighting output ON or OFF regardless of the state of the
main flame and changing the state of the main flame
will have no effect on the lighting output.
Continuous Pilot
Operation of this feature of having the pilot to run all the
time will be activated with the pressing of two buttons,
"PROG/TIME" & "FLAME 1". This action will activate
the Icon on the LCD screen. Pressing of the same two
buttons will de-activate the feature.
This feature is the same as the standard AF-4000
module, but activation of the system is different in that
two buttons must be depressed to activate or de-
activate the function. This feature can also be activated
via a 2-position switch on the side of the main module.