20007967
Connection to Gas Supply
NOTE: For Natural and Propane gas, you must have a manual
shutoff at the fireplace.
1. Place the burner pan in the fireplace. Pull the grate so the back
side of the hearth brick pulls up (1, Fig. 1) enough for you to tilt the
grate up (2, Fig. 1) to slide the pan underneath. (3, Fig. 1) The burn-
er should be located several inches from the backwall, centered left
to right.
NOTE:
This is for burner connection purposes only. Exact burner
placement will be covered on Page 7, after all connections have
been made.
3. Attach the Gas Supply Fitting onto your fireplace’s gas supply
pipe, as shown in Figure 2.
CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please con-
tact your dealer/distributor for assistance.
8” adjustable crescent wrench; Pipe thread sealant compound or teflon tape; 12” pipe wrench or channel lock pliers.
Tools Required
Gas Log
Minimum Firebox Dimensions
Minimum
Gas Supply
Set
Input
Width
Flue
Pressure
Size
Btu/hr
Back
Front
Depth Height
Size
Minimum
Maximum
24”
90,000
27”
36”
18”
18”
51 sq.in.
3.5” w.c.
7.0” w.c.
Minimum Clearances & Specifications
Natural Gas Units
Propane Gas Units
Gas Log
Minimum Firebox Dimensions
Minimum
Gas Supply
Set
Input
Width
Flue
Pressure
Size
Btu/hr
Back
Front
Depth Height
Size
Minimum
Maximum
24”
50,000
27”
36”
18”
18”
51 sq.in.
11.0” w.c.
14.0” w.c.
Pre-Installation Checklist
Yes
No
Is the gas type you are using the same as the gas type listed on the rating plate for this
appliance?
Does the firebox meet the minimum size dimensions below?
Is the gas supply inlet pressure correct? Refer to Table below.
Is your fireplace plumbed with gas on the right side (facing) of the fireplace? If not,
refer to page 5.
Is the gas supply line sized properly (Minimum 1/2” Iron pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one:
Have you checked local building codes? (Check with your local building department)
Does your fireplace have a wire mesh screen in place?
LG341
OD24
lift grate
5/04 djt
1
2
3
Fig. 1
Pull back of grate and hearth brick up, tilt front
of grate up and slide burner pan under.