background image

20007967

3

The Logsets have been designed and tested to oper-
ate safely when installed according to the installation 
instructions contained in this manual. Read all instruc-
tions before starting the installation.

• For outdoor use only.
• The logset should be inspected before use and at 
least annually thereafter. More frequent cleaning may 
be necessary because of excessive lint from carpeting 
or bedding material.
• In the United States, the installation and operation 
must conform to local codes or, in the absence of local 
codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, latest edition, CSA B149.1 Installation Code, 
and with the National Electrical Code, ANSI/NFPA70 
(latest edition).
• The gas logset and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 p.s.i.g. (3.5 kPa) The gas logset must be 
isolated from the gas supply piping system by closing 
its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pres-
sures equal to or less than 1/2 p.s.i.g. (3.5 kPa)
• Do not, under any circumstances, burn solid fuel 
(wood, paper, coal) in the fireplace where you have 
installed your logset. Do not use it for cooking. Put 
nothing on top of the logs.
• The logset 

must

 be compatible with its fuel. Natural 

gas requires different hardware than propane. Never 
attempt to use natural gas with a propane logset or vice 
versa. 
• For a propane burning logset, the supply tank must 
include a high to low gas pressure regulator. The tank 

must

 be outdoors. Do not, under any circumstances, 

locate supply tanks inside any structure.
• The fireplace 

must

 include a screen made of chain 

mesh or a similar material. You must keep the screen 
closed at all times during the operation of the logset; it 
will protect you in the event of an explosion.

• WARNING:

 If the fireplace contains glass doors, 

they 

must

 remain open at all times during the opera-

tion of the logset, allowing combustion air to circulate.
• In order to avoid any possible gas leaks, apply pipe 
joint compound to all non-flared threaded connections 
involved in this installation. For propane, the joint 
compound must be resistant to the corrosive action of 
propane.
• To check for leaks, always use a soapy water solu-
tion or a sniffer. 

Never

 test by using an open flame.

• The area around the gas logset 

must

 be free of all 

combustible materials, especially gasoline or other 
highly flammable, vapor producing liquids.
• Due to high temperatures, locate this logset away 
from both high traffic areas and furniture and draper-
ies.
• Children and adults alike should be aware of the 
high surface temperatures; to avoid the risk of burns 
or ignition of clothing they should stay away.
• Do not touch any part of the logset other than the 
controls while it is operating or immediately after you 
turn it off.
• Supervise young children and pets carefully when 
they are in the area where the logset is operating.
• Do not place clothing or other flammable material on 
or near the logset.
 •Make sure that any safety screen or guard, removed 
during servicing, has been replaced before you use 
the logset.
• It is imperative that you keep clear all burner areas, 
control compartments and passageways for circulat-
ing air.
• Do not move the logset in any way that might dis-
lodge the logs from their fixed positions. If you bump 
the logset check to see if you have dislodged any-
thing.
• Provide adequate clearances around air openings 
into the combustion chamber and adequate acces-
sibility clearance for servicing and proper operation. 
NEVER obstruct the front opening of the fireplace.

General Information

In order to assure a safe and effective instal-
lation, only a qualified service person who is 
familiar with the building codes and installation 
techniques appropriate to your area may install 
and service this appliance.

Содержание OD24SHKN

Страница 1: ...ED AGENCY INDIVIDUAL FIRM CORPORATION OR COMPANY EXPE RIENCED IN THE INSTALLATION REPAIR AND SERVICING OF THIS TYPE OF GAS APPLIANCE DO NOT MODIFY ALTER OR TAMPER WITH ANY PART OF THIS HEATER CONTROL OR LOGS INSTALLER PLEASE NOTE DO NOT BEGIN INSTALLATION OF THIS GAS LOGSET UNTIL ALL INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD Certified as CSA 7 94 U S manually lighted decorative gas appliance for i...

Страница 2: ...place screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air The log set and its individual shut off valve MUST be isolated from the gas supply piping system by closing its individual shut off valve during any pressure testing of gas supply at test pressures equal to o...

Страница 3: ...otect you in the event of an explosion WARNING If the fireplace contains glass doors they must remain open at all times during the opera tion of the logset allowing combustion air to circulate In order to avoid any possible gas leaks apply pipe joint compound to all non flared threaded connections involved in this installation For propane the joint compound must be resistant to the corrosive action ...

Страница 4: ... Maximum 24 90 000 27 36 18 18 51 sq in 3 5 w c 7 0 w c Minimum Clearances Specifications Natural Gas Units Propane Gas Units Gas Log Minimum Firebox Dimensions Minimum Gas Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 24 50 000 27 36 18 18 51 sq in 11 0 w c 14 0 w c Pre Installation Checklist Yes No Is the gas type you are using the same as the gas t...

Страница 5: ... of Fireplace CFM149 R CFL Gas Supply Connection 2 14 01 sta CFM149 Fig 2 Natural gas connection 4 Attach one end of the Flexible Gas Connector to the brass Burner Inlet Fitting which has been factory installed into the burner 5 Attach the other end of the Gas Connector to the flared side of the Gas Supply Fitting Remember to use pipe thread sealant or teflon tape only on the straight pipe threads D...

Страница 6: ...ng the bolt provided to the damper plate with an adjustable wrench Fig 5 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully open The proper finished installation of the Damper Stop is shown in Figure 6 If the bolt fails to block the damper in an open position the damper should be r...

Страница 7: ... of glowing embers so the mesh piece covers the burner pan material Fig 10 4 Open remaining bag of embers and place evenly on top of mesh screen Fig 10 5 Spread lava rock onto fireplace hearth around the burner pan for decorative purposes Fig 11 Fig 7 Grate placement FP1487 grate placement 5 10 04 djt 1 FP1487 FP1488 OD24 lava rock 5 10 04 djt Lava Rock FP1488 Fig 8 Lava rock placement Pan Assembly...

Страница 8: ...s are in notches provided Fig 13 FP1492 log placement 5 10 04 djt Front 2 Shorter Logs Back Log FP1149 Fig 12 OD24SHK log placement Grate Retainer Optional Glass Door Set The optional glass door set is for weather exposure protection of gas logs for the ODSRA Series fireplaces CAUTION The glass doors must be fully open when operating the gas log set Unit Model ODSR36A 36GDKSSSR ODSR42A 42GDKSSSR LG...

Страница 9: ...in which the log set is installed Appliance Break in During the 2 3 hour appliance break in period you may detect an odor from the appliance as the various water based paints used in the manufacture of this log set cure This is a normal and temporary situation that is not a cause for alarm To ensure proper curing of the logs 1 Ignite a 2 flame and maintain it for 1 2 hour 2 Burn the logs in consecu...

Страница 10: ...nstalled the correct orifice into the set Burner Is Excessively Noisy Please note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas pressure coming into the fireplace does not exceed the maximum pressure allowed with this gas set refer to tables on page 4 If you are using the gas logs with a safety pilot kit make sure you installe...

Страница 11: ...Rear Log 20007972 1d Left Front Log 20007974 1e Right Front Log 20007973 2 Bag of Glowing Embers 4310001 3 Bag of Lava Rock 3310046 4 Damper Stop 20002575 5 Pan Assembly 20007959 6 Orifice Natural Gas 20000961 7 Burner Inlet Fitting 20000958 8 Flexible Gas Connector 3304176 9 Gas Supply Fitting Elbow 3304145 10 3 8 Brass Female NPT to Flare Propane 3304146 11 Ember Screen 20007961 12 3 8 Brass Elbo...

Страница 12: ...espect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components referred to in those para graphs subject to the following conditions and limitations 1 These warranties are extended only to the Gas Ap pliance installed in the continental United States including Alaska and Canada only if and so long as the accordan...

Отзывы: