20007967
5
NOTE:
Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas on
the right side (facing). If your fireplace is plumbed with the gas on the left side remove fittings on right and
left side of straight burner tube and switch sides, at the same time put front burner tube on right side with
the elbow fitting. (Refer to Figs. 3,4)
You may also run a flexible connector (or as per local codes) along the back wall of the fireplace to bring
your gas line to the right hand side. You can then place the set in front of the flexible connector. (Fig. 4)
Gas Plumbed on Left Hand Side of Fireplace
CFM149
R-CFL Gas Supply Connection
2/14/01 sta
CFM149
Fig. 2
Natural gas connection.
4. Attach one end of the Flexible Gas Connector to
the brass Burner Inlet Fitting which has been factory
installed into the burner.
5. Attach the other end of the Gas Connector to the
flared side of the Gas Supply Fitting.
Remember to use pipe thread sealant or teflon tape
only on the straight pipe threads. Do not use on
any flared ends.
FP1484
OD24SHK
LP hook up
5/04 djt
Rigid Pipe. Flexible Hose or Copper Tubing
Approved for Outdoor Use
Gas Inlet 3/8”
Pipe Coupling
Parts Not
Supplied
Flex Hose
Regulator
Supplied w/LP Unit
FP1484
Fig. 3
LP gas connection.
To Gas Supply
3/8” Brass Elbow
NPT to Flare
FP1486
alternate left
side gas connection
5/10/04 djt
Fig. 4
Alternate left side gas connection.
FP1486
FP1485
FP1485
alternate left side
gas connection
5/10/04 djt