20007967

7

Grate Placement

Grate Assembly

Place grate assembly over top of burner so the 
front middle leg of the grate is 1

¹⁄₂

” back from 

the front edge of the main burner pan assembly. 
(Fig. 7)

Add Pan Material

1.  With burner pan and grate in place, open the 
bag of lava rock and spread it evenly across the 
pan assembly to the top of the pan assembly. (Fig. 
8)
2.  Open one bag of glowing embers and place 
evenly across burner covering lava rock. (Fig. 9) 
3.  Slide the mesh screen under the grate, but on 
top of glowing embers so the mesh piece covers 
the burner pan material. (Fig. 10)
4.  Open remaining bag of embers and place 
evenly on top of mesh screen. (Fig. 10)
5.  Spread lava rock onto fireplace hearth around 
the burner pan for decorative purposes. (Fig. 11)

Fig. 7 

 Grate placement.

FP1487

grate placement

5/10/04  djt

1

¹⁄₂

"

FP1487

FP1488

OD24 lava rock

5/10/04 djt

Lava 

Rock

FP1488

Fig. 8  

Lava rock placement.

Pan 

Assembly

FP1489

ember placement

5/10/04  djt

Glowing Embers

FP1489

Fig. 9

  Ember placement.

FP1490

screen placement

5/10/04  djt

Ember Screen

Embers

FP1490

Fig. 10 

 Screen and ember placement.

FP1491

lava rock placement

5/10/04  djt

FP1491

Fig. 11

  Place lava rock on fireplace hearth for decoration.

Lava Rock

Содержание OD24SHKN

Страница 1: ...ED AGENCY INDIVIDUAL FIRM CORPORATION OR COMPANY EXPE RIENCED IN THE INSTALLATION REPAIR AND SERVICING OF THIS TYPE OF GAS APPLIANCE DO NOT MODIFY ALTER OR TAMPER WITH ANY PART OF THIS HEATER CONTROL OR LOGS INSTALLER PLEASE NOTE DO NOT BEGIN INSTALLATION OF THIS GAS LOGSET UNTIL ALL INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD Certified as CSA 7 94 U S manually lighted decorative gas appliance for i...

Страница 2: ...place screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air The log set and its individual shut off valve MUST be isolated from the gas supply piping system by closing its individual shut off valve during any pressure testing of gas supply at test pressures equal to o...

Страница 3: ...otect you in the event of an explosion WARNING If the fireplace contains glass doors they must remain open at all times during the opera tion of the logset allowing combustion air to circulate In order to avoid any possible gas leaks apply pipe joint compound to all non flared threaded connections involved in this installation For propane the joint compound must be resistant to the corrosive action ...

Страница 4: ... Maximum 24 90 000 27 36 18 18 51 sq in 3 5 w c 7 0 w c Minimum Clearances Specifications Natural Gas Units Propane Gas Units Gas Log Minimum Firebox Dimensions Minimum Gas Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 24 50 000 27 36 18 18 51 sq in 11 0 w c 14 0 w c Pre Installation Checklist Yes No Is the gas type you are using the same as the gas t...

Страница 5: ... of Fireplace CFM149 R CFL Gas Supply Connection 2 14 01 sta CFM149 Fig 2 Natural gas connection 4 Attach one end of the Flexible Gas Connector to the brass Burner Inlet Fitting which has been factory installed into the burner 5 Attach the other end of the Gas Connector to the flared side of the Gas Supply Fitting Remember to use pipe thread sealant or teflon tape only on the straight pipe threads D...

Страница 6: ...ng the bolt provided to the damper plate with an adjustable wrench Fig 5 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully open The proper finished installation of the Damper Stop is shown in Figure 6 If the bolt fails to block the damper in an open position the damper should be r...

Страница 7: ... of glowing embers so the mesh piece covers the burner pan material Fig 10 4 Open remaining bag of embers and place evenly on top of mesh screen Fig 10 5 Spread lava rock onto fireplace hearth around the burner pan for decorative purposes Fig 11 Fig 7 Grate placement FP1487 grate placement 5 10 04 djt 1 FP1487 FP1488 OD24 lava rock 5 10 04 djt Lava Rock FP1488 Fig 8 Lava rock placement Pan Assembly...

Страница 8: ...s are in notches provided Fig 13 FP1492 log placement 5 10 04 djt Front 2 Shorter Logs Back Log FP1149 Fig 12 OD24SHK log placement Grate Retainer Optional Glass Door Set The optional glass door set is for weather exposure protection of gas logs for the ODSRA Series fireplaces CAUTION The glass doors must be fully open when operating the gas log set Unit Model ODSR36A 36GDKSSSR ODSR42A 42GDKSSSR LG...

Страница 9: ...in which the log set is installed Appliance Break in During the 2 3 hour appliance break in period you may detect an odor from the appliance as the various water based paints used in the manufacture of this log set cure This is a normal and temporary situation that is not a cause for alarm To ensure proper curing of the logs 1 Ignite a 2 flame and maintain it for 1 2 hour 2 Burn the logs in consecu...

Страница 10: ...nstalled the correct orifice into the set Burner Is Excessively Noisy Please note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas pressure coming into the fireplace does not exceed the maximum pressure allowed with this gas set refer to tables on page 4 If you are using the gas logs with a safety pilot kit make sure you installe...

Страница 11: ...Rear Log 20007972 1d Left Front Log 20007974 1e Right Front Log 20007973 2 Bag of Glowing Embers 4310001 3 Bag of Lava Rock 3310046 4 Damper Stop 20002575 5 Pan Assembly 20007959 6 Orifice Natural Gas 20000961 7 Burner Inlet Fitting 20000958 8 Flexible Gas Connector 3304176 9 Gas Supply Fitting Elbow 3304145 10 3 8 Brass Female NPT to Flare Propane 3304146 11 Ember Screen 20007961 12 3 8 Brass Elbo...

Страница 12: ...espect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components referred to in those para graphs subject to the following conditions and limitations 1 These warranties are extended only to the Gas Ap pliance installed in the continental United States including Alaska and Canada only if and so long as the accordan...

Отзывы: