![Vermont Castings ICFDV40CNTSC Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/vermont-castings/icfdv40cntsc/icfdv40cntsc_installation-and-operating-instructions-manual_1006099037.webp)
20304852
ICFDV40 Fireplace Insert
37
CLEANING AND MAINTENANCE
Make sure the gas valve knob is in the “OFF” position.
Wait at least
fi
ve (5) minutes before start -ing maintenance.
VENTING SYSTEM
A quali
fi
ed agency should examine the venting system
annually.
CLEANING GLASS
Clean the ceramic glass periodically. Condensation will
sometimes form on the glass during a 0 startup. This is
normal for all gas
fi
replaces and inserts. This condensation
often attracts dust and lint to the surface of the glass. The
initial paint curing of the appliance can also leave a slight
fi
lm on the glass. This is a temporary problem.
You should clean the glass after the
fi
rst two weeks of use.
After that, you should clean the glass no more than two or
three times a season. Use a mild glass cleaner to clean
the door. Do not use abrasive cleaners. They will damage
the glass surface.
PILOT AND BURNER FLAMES
Visually check pilot and burner
fl
ames periodically.
Refer
to Figure 52
for typical burner
fl
ame.
Refer to Figure 53
for typical pilot
fl
ame.
Figure 52 -
Typical Burner Flame
LG1122
Figure 53 -
Typical Pilot Flame
Sensor
Thermopile
FP2453
FIREBOX CLEANING
1. Carefully remove log set, and embers from combustion
chamber.
2. Vacuum burner compartment thoroughly.
3. Vacuum any dust off logs.
4. Remove any lint from main burner and pilot.
5. Carefully replace log set, and embers in their correct
positions.
Refer to Pages 21 through 22.
6. Replace door.
7. Relight pilot.
Refer to Page 25.
8. Turn on main burners.
•
Allow logs to cool completely before
cleaning. Logs reach high temperatures.
•
Make sure clearances to combustibles
leave enough room for maintenance and
service.
•
Carefully reassemble and reseal insert
properly after any cleaning or servicing.
W
ARNING