14
20304852
ICFDV40 Fireplace Insert
VENTING INSTALLATION
INTAKE/EXHAUST MANIFOLD REMOVAL
AND VENT INSTALLATION
The intake/exhaust manifold is shipped attached to insert.
It may be removed to allow tight installation.
1. Unfasten the two (2) machine screws on the face of the
unit and release the plate assembly by sliding the plate
back.
2. Attach the exhaust and the intake
fl
ex pipes to the collar
on the plates with a hose clamp (not provided) or other
approved methods (check local codes).
3. Re-attach exhaust baf
fl
e and manifold assembly in
reverse order of Step 1.
Figure 12
Machine
Screws
Intake Collar
Exhaust/Intake
Slide Plate
Assembly
FP2979
Exhaust Collar
The unit is shipped from the factory as a natural gas unit
with the baf
fl
e installed. The baf
fl
e should be suf
fi
cient for
venting up to 20 feet (6 m) off the top of the unit. An extra
baf
fl
e plate is shipped with the unit for installations 20
feet and above. Adjust the plate to the closed position as
desired.
Figure 14
Loosen Four (4) Screws to Adjust
Bottom View
Closed Position
Bottom View
Open Position
FP1961
Figure 14 -
Baffl e Assembly and Adjustment
Plate
Assembly
Latch Tool
FP2977
Figure 13
4. While sliding unit in place, if necessary the glass latch/
shutoff tool can be used to help place the plate assem-
bly. Using the small end of the tool, insert it in the square
notch in top front of
fi
rebox. Hook the plate assembly
with tool and pull forward into place while sliding
fi
rebox
to the rear.
Figure 13
5. Reinstall and tighten machine screws.