5
203000245
VS38 Direct Vent Gas Stove
PRODUCT FEATURES
PRODUCT SPECIFICATIONS
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
•
For alcove installation see
“Clearances,”
Page 8.
ON/OFF
PIL
OT
HEA
T
OFF
FAN
ST1099
SS38 controls
Off/Pilot/On
Knob
Optional Remote
Receiver
Door
Figure 1 -
VS38 Stove Controls
Hi/Lo Knob
On/Off/RS
Switch
Blower
ST1099
INSTALLING ABOVE 2000 FEET
•
In the USA, the appliance must be derated 4% for every
1,000 ft. above 2,000 ft elevations.
•
In Canada, these applications are certified for altitudes
of 0 - 2,000 ft, and must be derated by 10% for installa-
tions between 2,000 and 4,500 ft. (derate an additional
4% for every 1,000 ft. above 4,500 ft. elevations.)
GAS PRESSURES
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
GAS SPECIFICATIONS & ORIFICE SIZE
Max.Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
SS38NV
Nat.
38,000
27,000
#32
SS38PV
LP
35,000
25,000
#50
The Discovery VS38 is equipped with a variable output
gas control.