VS38 Direct Vent Gas Stove

4.  Never install the stove 

•  

in a recreational vehicle

•  

where curtains, furniture, clothing, or other flam-
mable objects are less than 42" from the front, top, 
or sides of the stove

•  

in high traffic areas

•  

in windy or drafty areas 

5.  This stove reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 
clothing ignition. Stove will remain hot for a time after 
shutdown. Allow surfaces to cool before touching. 

6.  Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 
young  children  and  others  may  be  susceptible  to 
accidental contact burns. A physical barrier is recom-
mended if there are at risk individuals in the house. To 
restrict access to a fireplace or stove, install an adjust-
able safety gate to keep toddlers, young children and 
other at risk individuals out of the room and away from 
hot surfaces. 

7.  Do  not  modify  stove  under  any  circumstances. Any 

parts removed for servicing must be replaced prior to 
operating stove. 

8.  Turn stove off and let cool before servicing, installing, 

or  repairing.  Only  a  qualified  service  person  should 
install, service, or repair the stove. Have burner system 
inspected annually by a qualified service person. 

9.  You  must  keep  control  compartments,  burners,  and 

circulating air passages clean. More frequent cleaning 
may be needed due to excessive lint and dust from 
carpeting, bedding material, pet hair, etc. Turn off the 
gas valve and pilot light before cleaning stove. 

10.  Have venting system inspected annually by a quali-

fied service person. If needed, have venting system 
cleaned  or  repaired.  Refer  to 

Cleaning  and  Mainte-

nance

, Page 30. 

11.  Keep the area around your stove clear of combustible 

materials, gasoline, and other flammable vapor and liq-
uids. Do not run stove where these are used or stored. 
Do not place items such as clothing or decorations on 
or around stove. 

INSTALLER

Please leave these instructions with the owner.

OWNER

Please retain these instructions for future reference.

IMPORTANT SAFETY INFORMATION

This stove is a vented product. This stove must be properly 
installed by a qualified service person. The glass door must 
be properly seated and sealed. If this unit is not properly 
installed by a qualified service person with glass door prop-
erly seated and sealed, combustion leakage can occur. 

CARBON MONOxIDE POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 
dizziness  and/or  nausea.  If  you  have  these  signs,  the 
stove may not have been installed properly. Get fresh air at 
once! Have the stove inspected and serviced by a qualified 
service person. Some people are more affected by carbon 
monoxide  than  others.  These  include  pregnant  women, 
people with heart or lung disease or anemia, those under 
the influence of alcohol, and those at high altitudes. 
Propane/LP  gas  and  natural  gas  are  both  odorless. An 
odor-making agent is added to each of these gases. The 
odor helps you detect a gas leak. However, the odor added 
to these gases can fade. Gas may be present even though 
no odor exists.
Make certain you read and understand all warnings. Keep 
this manual for reference. It is your guide to safe and proper 
operation of this stove.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate.  This  appliance  is  not 
convertible for use with other gases unless a certified 
kit is used. 

2.  For propane/LP stove, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply 
tank(s) outdoors. To prevent performance problems, 
do  not  use  propane/LP  fuel  tank  of  less  than  100 
lbs. capacity. 

3.  If you smell gas

• 

shut off gas supply.

•  

do not try to light any appliance.

•  

do not touch any electrical switch; do not use any 
phone in your building .

•  

immediately call your gas supplier from a neigh-
bor’s  phone.  Follow  the  gas  supplier’s  instruc-
tions.

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, 
or service this stove. 

• 

Any change to this stove or its controls can be dangerous.

• 

Improper installation or use of this stove can cause serious injury or death from fire, 
burns, explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание Discovery VS38

Страница 1: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruction...

Страница 2: ...trical Wiring 23 Remote Wall Switch 23 Log Placement 24 PLEASE READ THE INSTALLATION OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE Thank you and congratulations on your purchase of a Vermont Cast...

Страница 3: ...instructions for future reference IMPORTANT SAFETY INFORMATION This stove is a vented product This stove must be properly installed by a qualified service person The glass door must be properly seate...

Страница 4: ...idth and depth of the appliance 18 Do not use stove if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 19 Do not operate...

Страница 5: ...see Clearances Page 8 ON O FF PILO T HE AT OF F FA N ST1099 SS38 controls Off Pilot On Knob Optional Remote Receiver Door Figure 1 VS38 Stove Controls Hi Lo Knob On Off RS Switch Blower ST1099 INSTAL...

Страница 6: ...this unit is installed in a mobile home it must be bolted securely to the floor with leg bolts NOTE Discovery VS38 model stove works without any electrical supply Figure 2 Stove Dimensions 2656O 673 m...

Страница 7: ...ce on a metal or wood panel extending the full width and depth of the appliance Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line For op...

Страница 8: ...ter Left and right clearances are determined when facing the front of the heater Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fir...

Страница 9: ...tem require a minimum of 1 clearance to combustible materials on all sides of the pipe Only a 1 clearance is required where the vent passes through the nearest vertical wall INSTALLATION PLANNING Ther...

Страница 10: ...s required for such venting WARNING Treatment of firestops and construction of the chase may vary from building type to building type These instructions are not substitutes for the requirements of loc...

Страница 11: ...er regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the com...

Страница 12: ...C Maximum depth of 48 1219mm for alcove location D Minimum width for back wall of alcove location Combustible 38 965mm Noncombustible 24 610mm E Clearance from corner in alcove location Combustible 6...

Страница 13: ...he appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have three locking lugs indentations These lugs will slide straig...

Страница 14: ...andoffs between vent cap and exterior wall The vinyl siding standoff prevents excessive heat from melting the vinyl siding material Bolt the vent cap to the standoff Apply non hardening mastic around...

Страница 15: ...NSTALLATION Table 1 Horizontal Venting Vertical V Minimum Horizontal H Maximum 5 30 6 8 8 20 NOTE This configuration is for use with corner installation also Figure 15 Horizontal Termination Configura...

Страница 16: ...in desired location Drop a plumb line down from the ceiling to the position of the burner system exit flue Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a...

Страница 17: ...the base of the flashing to the roof and framing with roofing nails Be sure roofing material overlaps the top edge of the flashing as shown in Figure 18 page 17 There must be a 1 clearance from the ve...

Страница 18: ...to 4 collar of stove or first vent secton as shown VENTING INSTALLATION Figure 21 Cathedral Ceiling Support Box Installation ST1108 cat clg support box Level Cathedral Ceiling Support Box 2 Minimum Be...

Страница 19: ...orizontal H H1 Minimum Maximum 8 2 9 4 10 6 11 8 23 8 H V1 V V ST1112 vert vent Table 7 Vertical Venting with Two 2 90 Elbows Vertical V V1 Horizontal H H1 Minimum Maximum 8 2 9 12 10 18 11 20 NOTE In...

Страница 20: ...gas line with gas connector if allowed by local codes not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CS...

Страница 21: ...o the stove Check your building codes for any special requirements for locating equipment shutoff valve to stoves Apply pipe joint sealant lightly to male threads This will prevent excess sealant from...

Страница 22: ...nob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figure...

Страница 23: ...I NFPA 70 latest edition and Canadian Electrical Code CSA C22 1 CAUTION Label all wires before disconnecting when servicing controls Wiring errors can cause improper and dangerous operation Verify pro...

Страница 24: ...Install Left Base Log Left Base Log FINAL INSTALLATION WARNING The positioning of the logs is critical to the safe and clean operation of this heater Sooting and other problems may result if the logs...

Страница 25: ...e 34 Figure 35 Install Top Left Log Top Left Log LG738 VS38 top left log LG738 6 Place top left log on left base log Line up the hole in the bottom of the top log with the locating pins on the bottom...

Страница 26: ...gs and Rock Wool Rock Wool Figure 38 Install Rock Wool Top Center Log Embers Pins FINAL INSTALLATION 8 Place top center log on top left log pins sand angle to burner Figure 37 LG740 9 Break up rock wo...

Страница 27: ...ed service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to...

Страница 28: ...the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in seri...

Страница 29: ...This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 40 Lighting the burner Dep...

Страница 30: ...for typical burner flame Refer to Figure 45 for typical pilot flame FIREBOX CLEANING 1 Carefully remove log set and embers from combustion chamber 2 Vacuum burner compartment thoroughly 3 Vacuum any...

Страница 31: ...adjusted for high altitude as follows To increase air mixture push up the adjustment rod located beneath the stove This opens the shutter more and will stop or minimize sooting Figure 46 To decrease a...

Страница 32: ...glass style frame slide new glass into the 45 aluminum post not shown 7 Fasten retaining brackets back into place with 5 16 nuts 8 Replace 7 8 rope Make sure the joint is at the bottom and there is no...

Страница 33: ...33 203000245 VS38 Direct Vent Gas Stove blower Blower wiring diagram for Blower ST1118 blower White Hi Temp ST1119 VS38 wiring diagram...

Страница 34: ...k for spark arcing from the electrode to pilot Adjust by loosen ing screws on pilot base Adjust and retighten 4 Replace with new wire 1 A Check for proper connection of thermocouple to rear of valve B...

Страница 35: ...35 203000245 VS38 Direct Vent Gas Stove replacement parts 1 4 17 9 14 13 6 15 16 19 7 10 5 11 12 2 21 24 22 3 18 AA Battery 25 23 20 8 2030245 VS38 parts...

Страница 36: ...F 1 43D0094 43D0094 43D0094 43D0094 15 Ignitor Battery Module 1 45D0077 45D0077 45D0077 45D0077 16 Ignitor Wire Harness 1 44D0500 44D0500 44D0500 44D0500 17 ON OFF Wire Harness 1 45D0565 45D0565 45D05...

Страница 37: ...x 6 Pipe 908B 7 Adjustable 11 14B Pipe 911B Wall Thimble 940 Cathedral Ceiling Support Box 941 Roof Flashing 0 12 6 12 943 Roof Flashing 7 12 12 12 943S 7 x 45 Elbow 945B Vinyl Siding Standoff 950 Sto...

Страница 38: ...y with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please re...

Страница 39: ...e or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by mechanical systems such as furnaces fans clothes dryers etc Terms Th...

Страница 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: