VS38 Direct Vent Gas Stove

OPERATING INSTRUCTIONS

A. 

This appliance is equipped with a pilot which must be lit with built-in battery ignitor while 
following these instructions exactly.

B. 

BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

 

•  Turn off all gas to the appliance.

 

•  Open windows. 

 

•  Do not attempt to light any appliance.

 

•  Do not touch any electric switch; do not use any phone in your building.

 

•  Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's 

instructions.

 

•  If you cannot reach your gas supplier, call the fire department.

C.  

Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will 
not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force 
or attempted repair may result in a fire or explosion.

D. 

 Do not use this appliance if any part of it has been under water. Immediately call a qualified 

service technician to inspect the appliance and to replace any part of the control system 
and any gas control that has been under water.

If you do not follow these instruction 
exactly, a fire or explosion may result 
causing  property  damage,  personal 
injury or loss of life.

W

ARNING

 FOR YOUR SAFETY READ BEFORE LIGHTING 

LIGHTING PILOT FOR THE FIRST TIME  

INITIAL LIGHTING 

Purge air from the supply line as follows: 
 

•  Open main shutoff valve.

 

•  Unscrew main pressure test point.

 

•  Leave inlet test screw open until gas comes in.

 

•  When gas is flowing, tighten inlet screw immediately. 

LEAK TESTING

1.  Follow the pipe from the gas supply line connection to the gas valve. Check connection for 

leaks with soap and water mixture. 

2.  Next check for gas leaks at the burner with soap and water mixture.
3.   Check the pilot for gas leaks with soap and water mixture.

Never  use  an  open  flame  to 
check for gas leak. 

W

ARNING

Содержание Discovery VS38

Страница 1: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruction...

Страница 2: ...trical Wiring 23 Remote Wall Switch 23 Log Placement 24 PLEASE READ THE INSTALLATION OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE Thank you and congratulations on your purchase of a Vermont Cast...

Страница 3: ...instructions for future reference IMPORTANT SAFETY INFORMATION This stove is a vented product This stove must be properly installed by a qualified service person The glass door must be properly seate...

Страница 4: ...idth and depth of the appliance 18 Do not use stove if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 19 Do not operate...

Страница 5: ...see Clearances Page 8 ON O FF PILO T HE AT OF F FA N ST1099 SS38 controls Off Pilot On Knob Optional Remote Receiver Door Figure 1 VS38 Stove Controls Hi Lo Knob On Off RS Switch Blower ST1099 INSTAL...

Страница 6: ...this unit is installed in a mobile home it must be bolted securely to the floor with leg bolts NOTE Discovery VS38 model stove works without any electrical supply Figure 2 Stove Dimensions 2656O 673 m...

Страница 7: ...ce on a metal or wood panel extending the full width and depth of the appliance Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line For op...

Страница 8: ...ter Left and right clearances are determined when facing the front of the heater Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fir...

Страница 9: ...tem require a minimum of 1 clearance to combustible materials on all sides of the pipe Only a 1 clearance is required where the vent passes through the nearest vertical wall INSTALLATION PLANNING Ther...

Страница 10: ...s required for such venting WARNING Treatment of firestops and construction of the chase may vary from building type to building type These instructions are not substitutes for the requirements of loc...

Страница 11: ...er regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the com...

Страница 12: ...C Maximum depth of 48 1219mm for alcove location D Minimum width for back wall of alcove location Combustible 38 965mm Noncombustible 24 610mm E Clearance from corner in alcove location Combustible 6...

Страница 13: ...he appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have three locking lugs indentations These lugs will slide straig...

Страница 14: ...andoffs between vent cap and exterior wall The vinyl siding standoff prevents excessive heat from melting the vinyl siding material Bolt the vent cap to the standoff Apply non hardening mastic around...

Страница 15: ...NSTALLATION Table 1 Horizontal Venting Vertical V Minimum Horizontal H Maximum 5 30 6 8 8 20 NOTE This configuration is for use with corner installation also Figure 15 Horizontal Termination Configura...

Страница 16: ...in desired location Drop a plumb line down from the ceiling to the position of the burner system exit flue Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a...

Страница 17: ...the base of the flashing to the roof and framing with roofing nails Be sure roofing material overlaps the top edge of the flashing as shown in Figure 18 page 17 There must be a 1 clearance from the ve...

Страница 18: ...to 4 collar of stove or first vent secton as shown VENTING INSTALLATION Figure 21 Cathedral Ceiling Support Box Installation ST1108 cat clg support box Level Cathedral Ceiling Support Box 2 Minimum Be...

Страница 19: ...orizontal H H1 Minimum Maximum 8 2 9 4 10 6 11 8 23 8 H V1 V V ST1112 vert vent Table 7 Vertical Venting with Two 2 90 Elbows Vertical V V1 Horizontal H H1 Minimum Maximum 8 2 9 12 10 18 11 20 NOTE In...

Страница 20: ...gas line with gas connector if allowed by local codes not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CS...

Страница 21: ...o the stove Check your building codes for any special requirements for locating equipment shutoff valve to stoves Apply pipe joint sealant lightly to male threads This will prevent excess sealant from...

Страница 22: ...nob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figure...

Страница 23: ...I NFPA 70 latest edition and Canadian Electrical Code CSA C22 1 CAUTION Label all wires before disconnecting when servicing controls Wiring errors can cause improper and dangerous operation Verify pro...

Страница 24: ...Install Left Base Log Left Base Log FINAL INSTALLATION WARNING The positioning of the logs is critical to the safe and clean operation of this heater Sooting and other problems may result if the logs...

Страница 25: ...e 34 Figure 35 Install Top Left Log Top Left Log LG738 VS38 top left log LG738 6 Place top left log on left base log Line up the hole in the bottom of the top log with the locating pins on the bottom...

Страница 26: ...gs and Rock Wool Rock Wool Figure 38 Install Rock Wool Top Center Log Embers Pins FINAL INSTALLATION 8 Place top center log on top left log pins sand angle to burner Figure 37 LG740 9 Break up rock wo...

Страница 27: ...ed service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to...

Страница 28: ...the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in seri...

Страница 29: ...This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 40 Lighting the burner Dep...

Страница 30: ...for typical burner flame Refer to Figure 45 for typical pilot flame FIREBOX CLEANING 1 Carefully remove log set and embers from combustion chamber 2 Vacuum burner compartment thoroughly 3 Vacuum any...

Страница 31: ...adjusted for high altitude as follows To increase air mixture push up the adjustment rod located beneath the stove This opens the shutter more and will stop or minimize sooting Figure 46 To decrease a...

Страница 32: ...glass style frame slide new glass into the 45 aluminum post not shown 7 Fasten retaining brackets back into place with 5 16 nuts 8 Replace 7 8 rope Make sure the joint is at the bottom and there is no...

Страница 33: ...33 203000245 VS38 Direct Vent Gas Stove blower Blower wiring diagram for Blower ST1118 blower White Hi Temp ST1119 VS38 wiring diagram...

Страница 34: ...k for spark arcing from the electrode to pilot Adjust by loosen ing screws on pilot base Adjust and retighten 4 Replace with new wire 1 A Check for proper connection of thermocouple to rear of valve B...

Страница 35: ...35 203000245 VS38 Direct Vent Gas Stove replacement parts 1 4 17 9 14 13 6 15 16 19 7 10 5 11 12 2 21 24 22 3 18 AA Battery 25 23 20 8 2030245 VS38 parts...

Страница 36: ...F 1 43D0094 43D0094 43D0094 43D0094 15 Ignitor Battery Module 1 45D0077 45D0077 45D0077 45D0077 16 Ignitor Wire Harness 1 44D0500 44D0500 44D0500 44D0500 17 ON OFF Wire Harness 1 45D0565 45D0565 45D05...

Страница 37: ...x 6 Pipe 908B 7 Adjustable 11 14B Pipe 911B Wall Thimble 940 Cathedral Ceiling Support Box 941 Roof Flashing 0 12 6 12 943 Roof Flashing 7 12 12 12 943S 7 x 45 Elbow 945B Vinyl Siding Standoff 950 Sto...

Страница 38: ...y with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please re...

Страница 39: ...e or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by mechanical systems such as furnaces fans clothes dryers etc Terms Th...

Страница 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: