![Vermont Castings CSDV30NVEMBCSB Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/vermont-castings/csdv30nvembcsb/csdv30nvembcsb_installation-and-operating-instructions-manual_1006257030.webp)
30
20306757
CSDV Series Direct Vent Gas Stove
OPERATING INSTRUCTIONS
ADJUSTING THE AIR SHUTTER (NG ONLY)
The venturi of the burner is equipped with an air shutter. The
opening of the venturi has been set at 1/4" for Natural Gas
and fully open for Propane installation at sea level. Natural
Gas Models may be adjusted for high altitude as follows:
• To increase air mixture, pull down the adjustment rod
located beneath the stove. This opens the shutter
more and will stop sooting.
Figure 37
• To decrease air mixture, push up the adjustment rod
located beneath the stove. This closes the shutter.
Flames will be more yellow.
Figure 38
ST1150
air shutter closed
Air Shutter
Adjustment
Rod
Figure 37 -
Push Adjustment Rod Up to Close Air Shutter
Lg1151
air shutter open
Air Shutter
Adjustment
Rod
Figure 38 -
Pull Adjustment Rod Down to Open Air Shutter