28
20306757
CSDV Series Direct Vent Gas Stove
OPERATING INSTRUCTIONS
LIGHTING PILOT FOR THE FIRST TIME
W
ARNING
Never use an open flame to check
for gas leaks.
INITIAL LIGHTING
Purge air from the supply line as follows:
• Open main shutoff valve.
• Unscrew main pressure test point.
• Leave inlet test screw open until gas
comes in.
• When gas is flowing, tighten inlet screw
immediately.
W
ARNING
If using a soap and water solutiong
to test for leaks, DO NOT spray
solution onto control body.
LEAK TESTING
You may check for gas leaks with the following
methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections
• Field made joints / gas shutoff valve
• Pilot
• Factory made joints
• Each joint or connection
• All joints on valve and control body
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. The elec
-
tronic ignitor will automatically ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat Steps 1 and 2.
Pilot Position
LIGHTING PILOT
PILOT
OF
F
P
IL
O
T
ON
FP1935
control knob pilot
The control has an interlock device that does not allow the lighting of the
stove up to the moment the safety device of the flame has not interrupted
the gas flow. After that period of time (when the magnet is closed), it is
possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any
tools during this operation. Damaged knobs may result in serious injury.
W
ARNING