Chateau™ Decorative Gas Appliance

20009543

FP1461

thru wall trim

3/17/04  djt

2” 

(51mm)

1” 

(25mm)

Min.

1” (25mm) Min.

16

¹⁄₄

” x 16

¹⁄₄

(413 x 413mm) 

Opening

FP1461

Fig. 25

  A 2” (51mm) thick trim is required around opening.

Zero clearance sleeve is only required for 
combustible walls.

STEP 3

Slide the zero clearance sleeve through the wall and 
install the firestop on the inside surface of the wall. 
Secure with four (4) #8 sheet metal screws.

STEP 4

Place fireplace into position. (Fig. 21) Measure the 
vertical height (X) required from the base of the flue 
collars to the center of the wall opening. 

NOTE:

 If using 

the SK8DVSK Kit, the vertical section of pipe is tele-
scopic and could provide adjustment from 24” up to 40” 
(610mm to 1016mm). Through the wall section shipped 
with the starter kit will not be used when going through 
the wall.

STEP 5

Tape the inner and outer flue collars of the fireplace 
using UL approved metal adhesive tape to ensure the 
joints are sealed.  Attach an appropriate length of vent 
pipe to the fireplace. Follow with the installation of the 
inner and outer elbow, tape elbow joints and secure 
joints as described on Page 11.

Sealing firestop gaps with high temperature sealant 
will restrict cold air being drawn in around fire-
place.
STEP 6

Before installing the termination, a 2” (51 mm) thick trim 
or frame is required around the the 16

¹⁄₄

” x 16

¹⁄₄

” (413 x 

413 mm) square opening to allow the vent termination 
to go directly onto the elbow. (Fig. 25)

STEP 7

Guide the vent terminations 8” and 11” collars into their 
respective vent pipes. Double check that the vent pipes 
overlap the collars by 2” (51 mm). Secure the termina-
tion to the wall with screws provided and caulk around 

Installing the 38S2VDK Door

When installing the DVT38S2 on an outside wall, the 
following steps must be taken into consideration. 

Fail-

ure to do so will result in a major reconstruction 
and CFM Corporation will not be responsible for 
costs associated with incorrect installation.

• 

If the unit is to be installed flush with the wall, a 1/4” 
(6 mm) clearance is required on both sides and top 
of surround around the glass frame assembly in 
order for the door to be accessible. (Refer to Page 4, 
Fig. 2)

• 

If the unit is recessed 3/4” (19 mm) from the wall, 
then no extra clearances are needed around the sur-
round.

• 

The unit must be installed with the stationary glass 
facing the outside (control panel assembly will be 
located on the left hand side of the unit when facing 
the unit from inside the house).

• 

The control panel assembly must only be installed 
on an inside wall.

Package contents:

• 

1, Glass frame assembly

• 

2, Brackets

• 

2, Short machine screws

• 

2, Long machine screws

• 

4, sheet metal screws

Installation Procedure

1.  If the unit is installed flush with the wall, a high tem-

perature sealant must be applied to seal around the 
surround around the glass frame assembly 3/4” (19 
mm) of the front edge of the surround. (Fig. 26)

the wall plate to weatherproof. (Fig. 25) As an alterna-
tive to screwing the termination directly to the wall you 
may also use expanding plugs or an approved exterior 
construction adhesive.

• • • • • • • • • • • •
• •• • • •••• • • •• • • •• • ••••••••••••••••••••
• •• • • • • •

3/4"

(19mm)

Glass Frame As-

sembly

High Temperature 

Sealant

Surround

FP1480

Fig. 26

  Apply high temperature sealant on surround around 

glass frame assembly when unit is installed flush with wall.

Содержание Chateau DVT38S2

Страница 1: ...ice must be performed by a quali ed installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch Do not use any phone in...

Страница 2: ...eneral Information Assembling Vent Pipes 11 SK8 Venting Pipes 11 Restrictor Plate Guide 12 Horizontal Termination 12 Vertical Termination 12 Sidewall Applications 13 Sidewall Installation 14 Sidewall...

Страница 3: ...le or any combustible material other than wood this replace must be installed on a metal or wood panel extending the full width and depth of the replace 12 This replace requires adequate ventilation a...

Страница 4: ...ded especially if the mantel is not available at the time of framing A framing stud is allowed to be placed on the inside of the 6 152 mm standoff on the side of the unit where the conduit is located...

Страница 5: ...ce is dependent on the depth of the mantel This also applies to the distance between the mantel leg if tted and the replace For the correct mounting height and widths refer to Figs 3a and 3b the follo...

Страница 6: ...the valve box assembly to the framing members open the box door remove extension knob s remove the valve cover by removing the two 2 screws securing the valve cover to the box hold the cover plate wi...

Страница 7: ...pper tubing or 1 2 gas tight Some municipalities have additional local codes it is always best to consult your local authority and the CSA B149 1 installation codes For USA installations consult the c...

Страница 8: ...ed with an ON OFF rocker switch at the valve box assembly If a wall switch is desired fol low these instructions 1 The valve box is equipped with two knockouts at the top right and left corners The ri...

Страница 9: ...Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent termi nation area after snow falls and clear to prevent ac cidental blockage of venting system When...

Страница 10: ...nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other appliances appliances 10 0...

Страница 11: ...The venting system must conform with local codes and or the current National Fuel Gas code ANSI Z223 1 NFPA 54 Only venting components manufactured by CFM Cor poration can be used in Direct Vent syste...

Страница 12: ...ow May use one 1 elbow only Restrictor Plate Guide Application NG LP SK8DVSK or 2 610mm vertical elbow 2 610mm horizontal None None 4 1 2m vertical elbow 4 ue 10 3m horizontal elbow None restrictor 8...

Страница 13: ...al vent length of vent pipe from the ue collar of the re place to the face of the outer wall Horizontal plane means no vertical rise exists on this portion of the vent assembly The maximum number of 9...

Страница 14: ...r and outer ue collars of the replace using UL approved metal adhesive tape to ensure the joints are sealed Attach an appropriate length of vent pipe to the replace Follow with the installation of the...

Страница 15: ...Facing Outside CAUTION Unit must be installed with stationary glass facing outside Control panel assembly will be located on the left side of the unit when facing the unit form inside house Failure t...

Страница 16: ...e check that the vent pipes overlap the collars by 2 51 mm Secure the termina tion to the wall with screws provided and caulk around Installing the 38S2VDK Door When installing the DVT38S2 on an outsi...

Страница 17: ...3 7m or greater measured from the top of the ue collar the restrictor plate as supplied with this unit should be used Fig 28 Refer to Page 21 Figure 37 for restrictor plate installation X FP1461 Fig...

Страница 18: ...ousing fettle andirons logs and glowing embers in reverse order Refer to Page xx for log installation Pipe Straps Every 3 914mm FP1463 Fig 32 Support straps for horizontal runs Max 20 6m Max Height 40...

Страница 19: ...use the appropriate starter kit Refer to Venting Components List The minimum height of the vent above the highest point of penetration through the roof is 2 610 mm Fig 37 FP593 SR C 11 20 97 Attic In...

Страница 20: ...02 sta CFM190 Fig 37 Minimum termination to roof clearance FP270 271 CR Series 2 19 99 djt Support Structure Elbow Strap must be tight Ceiling Hole Framing Angled Firestop Chimney Support Strap must...

Страница 21: ...act with AIS SK the chimney system Chimney Support Used to support chimney for each of 30 vertical SKCS8 height and 6 of angled chimney run Round Top Termination Top used to terminate chimney at roof...

Страница 22: ...each operating season depending on the environment in the house Clean the glass after the rst two weeks of operation The use of any non approved replacement glass will void all product warranties Car...

Страница 23: ...fractories already installed 6 Reinstall the burner tube and fettle FP1580 DVT38s2 refractory 6 05 Refractory Left Side Refractory Right Side FP1580 Fig 40 Ceramic refractory panels Refractory Left He...

Страница 24: ...ettle and set down over the burner tube assembly Repeat the same procedure on the opposite side 5 Position the log pilot plumbing Fig 44 Hold the log with the two 2 branches facing down and set it dow...

Страница 25: ...in positioning the log Hold the log with the at surface facing down and the burned out end closer to you NOTE Position this log through the side with the con trol valve box on the left side Set the l...

Страница 26: ...P390 FLAME ADJUSTMENT KNOB 11 21 96 SIT 820 Valve Fig 53 Flame adjustment knob for SIT valve Flame Temperature Adjustment RN RP EN EP Models For units equipped with HI LO valves the ame adjustment is...

Страница 27: ...ure the bottom is over lapping the bottom trim piece The right side of the trim should butt up against the right side nailing ange of the replace 3 Place the left trim on the left side of the window f...

Страница 28: ...some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch Do not use any phone in your building Immediatel...

Страница 29: ...h in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re or explosion D Do not use this appliance if any part has been under water...

Страница 30: ...burner assembly utilizes both a thermocouple and a thermopile The thermocouple operates the main valve operation On and Off Clean and or adjust pilot for maximum ame impingement on thermopile and ther...

Страница 31: ...ply Tubing And Pressures Are Good And Pilot Burner Orifice Is Not Blocked Check Electrical Connections Between Module And Pilot Operator On Gas Control Check For 24vac Across Pv mvpv Terminals On Modu...

Страница 32: ...tte trousse L installation n est pas termin e tant que le fonc tionnement de l appareil converti n a pas t v ri selon la notice du fabricant qui accompagne la trousse ATTENTION Avant d effectuer la co...

Страница 33: ...LO pressure regulator assembly to the valve using the new screws E supplied with the kit Tighten the screws securely Ref torque in lb Fig 62 15 Install the enclosed identi cation label F to the valve...

Страница 34: ...acuum burner compartment especially around ori ce primary air openings 6 Visually inspect pilot Brush or blow away any dust or lint accumulation 7 Reinstall logs 8 Ignite pilot Refer to Lighting Instr...

Страница 35: ...e without notice DVT38S2 Decorative Gas Appliance 1a 1b 2 1e 1 2 3 6 7a 8 9a b 10a b 11a b 12a b THTP TP TH 12c d 13a b 13c d 18 MV MVPV PV GND BURNER 24V GND 24V SENSE SPARK 19 20 26 9543 DVT38s2 par...

Страница 36: ...76 5 Spring Latch Assembly 20005788 6 Burner Housing Assembly 20009392 7a Burner 20009311 7b Burner Tube Assembly Pilot Side 20009308 8 Manifold Tube Assembly 20009282 9a Burner Housing Ori ce 55 LP 3...

Страница 37: ...lpack Tube not shown 53326 30 Screw 1 4 20 x 1 5 Black Pan Quad Glass Frame Screw 20006471 31 Tube Pilot 1 4 OD x 76 Long 20008828 32 1 4 Shear off Nut for Pilot Connection 20009102 33 1 4 Shear off N...

Страница 38: ...he control box spacer Fit the control box tight against the spacer G and the frame piece above Fasten the control box to the frame piece with 1 screws through the holes in the top of the control box F...

Страница 39: ...pection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warrant...

Страница 40: ...Ratings Model EnerGuide Ratings Fireplace Ef ciency DVT38S2RN 47 1 DVT38S2RP 47 1 DVT38S2EN 48 2 DVT38S2EP 48 2 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Co...

Отзывы: