BUF Vent-Free Fireboxes
HEARTH DIMENSIONS and FIREBOx LOCATION
A
B
C
D
E
FP2901
hearth dims
Ref.
BUF400
BUF500
A
35
Z\x
"
41
Z\x
"
B
17"
17"
C
20
C\,
"
26
C\,
"
D
21
Z\x
"
21
Z\x
"
Figure 2 -
Minimum Hearth Dimensions
FIREBOx LOCATION
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
•
Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles
must be main-
tained.
•
Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.
•
Installation must provide adequate ventilation and com-
bustion air.
•
Location should be out of high traffic or windy or drafty
areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE,
CLOTHING OR OTHER FLAMMABLE OBJECTS ARE
LESS THAN 42" FROM FRONT OF HEATER.
•
Never obstruct the front opening of the vent-free firebox
or restrict the flow of combustion and ventilation air.
•
Minimize modifications to existing construction. Refer
to
Figure 3
below for location suggestions.
•
Do not install in the vicinity where gasoline or other
flammable liquids may be stored. The vent-free firebox
must be kept clear and free from these combustible
materials.
FP2440
fireplace locations
FP2440
Figure 3 -
Location of Firebox