background image

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

CFM Specialty Home Products

Installation and Operation Instructions for Vented Gas 

Log Set - DragonFire Hearth Kits

 

FOR YOUR SAFETY:

DO NOT STORE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS NEAR THIS OR ANY 
OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

• 

SHUT OFF ALL GAS TO THE APPLIANCE.

• 

OPEN WINDOWS; DO NOT TOUCH ANY ELECTRICAL SWITCHES. DO NOT USE ANY PHONE IN 
YOUR BUILDING.

• 

DO NOT TRY TO LIGHT ANY APPLIANCE; EXTINGUISH ANY OPEN FLAME

• 

IMMEDIATELY PHONE YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.  FOLLOW THE SUPPLI-
ER’S INSTRUCTIONS.

• 

IF YOU CANNOT REACH THE GAS SUPPLIER, PHONE THE FIRE DEPARTMENT.

W A R N I N G 

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, 
CAUSING PROPERTY DAMAGE, INJURY, OR LOSS OF LIFE. 

ATTENTION

INSTALLATION AND SERVICE MUST BE PER-

FORMED BY A QUALIFIED AGENCY, INDI-

VIDUAL, FIRM, CORPORATION, OR COMPANY, 

EXPERIENCED IN THE INSTALLATION, REPAIR, 

AND SERVICING OF THIS TYPE OF GAS APPLI-

ANCE. DO NOT MODIFY, ALTER OR TAMPER 

WITH ANY PART OF THIS HEATER, CONTROL, 

OR LOGS. INSTALLER, CHECK LOCAL CODES 

BEFORE INSTALLING THIS LOG SET. IN SOME 

AREAS OF THE COUNTRY GAS LOG SETS ARE 

RESTRICTED.

INSTALLER PLEASE NOTE:

DO NOT BEGIN INSTALLATION OF THIS GAS 

LOG SET UNTIL ALL INSTRUCTIONS HAVE BEEN 

READ AND UNDERSTOOD. AFTER INSTALLA-

TION, LEAVE THESE INSTRUCTIONS WITH THE 

OWNER. 

SAVE THIS MANUAL FOR FUTURE REFERENCE

20003903  4/05  Rev. 9

DECORATIVE GAS APPLIANCE FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES

Design Certified to ANSI Z21.60 and CGA 2.26 Standards

READ THESE INSTRUCTIONS AND FOLLOW 
THE WARNINGS. PLEASE RECORD YOUR 
GAS LOG’S MODEL NUMBER FOR FUTURE 
REFERENCE:  

OWNER PLEASE NOTE:

Models A18CFLRN/P, A24CFLRN/P, A30CFLRN/P

CERTIFIED

DESIGN

CERTIFIED

Содержание A18CFLRN

Страница 1: ...T CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE ATTENTION INSTALLATION AND SERVICE MUST BE PER FORMED BY A QUALIFIED AGENCY INDI VIDUAL FIRM CORPORATION OR COMPANY EXPERIENCED IN THE INSTALLATION REP...

Страница 2: ...fuel or fuel combustion which are known to the state of California to cause can cer birth defects or other reproductive harm Do not use this appliance or any part that has been under water Immediately...

Страница 3: ...place supply tanks inside any structure G Never use sand or other dense pan material with propane gas use vermiculite only H Be sure to apply pipe joint compound to all non ared threaded connections...

Страница 4: ...uali ed installer must install one Have you checked local building codes Check with your local Building Dept Does you replace have a wire mesh screen in place Propane Gas Units Minimum Clearances Spec...

Страница 5: ...a template to drill two 2 1 8 holes in the Damper Locking Bracket to mount the Damper Stop NOTE Your gas log set is assembled at the factory to be installed in a replace plumbed with the gas on the ri...

Страница 6: ...the vent is prop erly drawing it up the chimney If the smoke is drawn back into the room extinguish the ame and remove any obstruction until proper venting is achieved If that fails check with a quali...

Страница 7: ...bers and place them on top of the Silica Sand evenly across the Burner Pan Be sure to separate the Glowing Embers into very small pieces before placing them onto the Silica Sand Remote Installation Co...

Страница 8: ...mes should come up directly between these two logs 4 Next place the smaller top logs diagonally onto the bottom logs The top logs can be arranged to achieve your desired ame pattern Refer to Figures 1...

Страница 9: ...FF position before turning the control knob ON If pilot goes out repeat steps 4 and 5 9 Turn ON OFF RS switch to ON or remote position Turn remote switch to ON 10 Flame is adjustable by rotating the H...

Страница 10: ...re coming into the replace does not ex ceed the maximum pressure allowed with this gas set refer to tables on Page 4 Match Lighting Burner is Excessively Noisy Please note The movement and combustion...

Страница 11: ...the Piezo wire is not loose call our customer service line Incorrect Pilot Ori ce Make sure the correct Pilot Ori ce is installed green for Natural Gas red for propane Incorrect gas supply pressure Ma...

Страница 12: ...any time without notice A18 24 30CFL DragonFire with Remote Pilot Ref Description A18CFLR A24CFLR A30CFLR 1 Complete Log Set 20004307 20004308 20004309 1a Outside Left Cross Log NNS2 n a n a 20004600...

Страница 13: ...304045 4304045 16 Flexible Gas Connector 3304176 3304176 3304176 17 Ori ce Wrench LP units 3309025 3309025 3309025 18a Pan and Extension Assembly 20003840 20003841 20003842 18b Burner Tube 3 8 2000382...

Страница 14: ...14 20003903...

Страница 15: ...anties speci ed in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: