5
20306747
DVM Series Direct Vent Gas Fireplace
PRODUCT FEATURES
• This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
• This appliance is not for use with solid fuels.
• The appliance is approved for bedroom or bedsitting
room installations.
• The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
• This appliance is mobile home approved.
• The appliance must be properly connected to a venting
system.
• The appliance is not approved for closet or recessed
installations.
PRODUCT SPECIFICATIONS
FP2407
DVM/MDV features
Off/Pilot/On Knob
Optional Remote Receiver
Figure 1 -
500DVM and 600DVM Fireplace
(Millivolt Unit Shown —
Also Available with
Signature Command System)
Hi/Lo Knob
Blower Control
On/Off/RS Switch
Ignitor
1/2"
Nailing
Flange
5/8" Nailing
Flange
1/2"
Nailing
Flange
Eyebrow
Insulation
Board
Standoff
FP2407
GAS PRESSURES
Model
Fuel
Max.
Input
BTU/h
Min.
Input
BTU/h
Orifice
Size
500DVMNSC
Nat.
30,000 21,500
7/64"
600DVMNSC
Nat.
32,000 22,000
#34
500DVMPSC
LP
30,000 23.500
#51
600DVMPSC
LP
32,000 26,000
#50
GAS SPECIFICATIONS & ORIFICE SIZE
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installa-
tions must be in accordance with the current ANSI Z223.1/
NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations above
4,500 feet (1,370 m).
Do not remove insulation board.
WARNING
Natural
Propane (LP)
Inlet Minimum
4.0” w.c.
11.0” w.c.
Inlet Maximum
14.0” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.