DVM Series Direct Vent Gas Fireplace
FIREPLACE INSTALLATION
FP1909a
signature command valve
alternate view
8/08
CHECK GAS PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace,
STOP!
Do not install the
appliance. Contact your dealer immediately.
2. To ease installation, a 24" (610 mm) flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach 1/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a solution of 50/50 water and
soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 47.
After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks.
Figure 47 -
Signature Command Valve
Pressure Inlet
Pilot Adjustment
Screw
Pressure Outlet
FP1909a
ELECTRICAL WIRING
General
1. This fireplace is equipped with the Signature Control
valve which operates on 6 volts. The 6 volt DC adapter
plugs into the fireplace junction box A/C power supply.
Four (4) “AA” batteries are used for back up during
power outages.
2. The Signature Command System can also be operated
without A/C power. The system can run on four (4) “AA”
batteries for approximately six (6) months under normal
use.
3. A/C power must be used to power the A/C module,
blowers, lights and AUX accessories if used with this
fireplace.
Optional Accessory Requirements
1. This fireplace may be used with a wall switch, wall
mounted thermostat and/or Signature Command wire-
less controls.
2. The command center control may be mounted on the
wall with the use of the SCSWEK 15ft. wall mount
extension kit.
CAUTION
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and
dangerous operation.
Do not use open flame to check for gas leaks.
WARNING
Electrical connections should only be performed by a
qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest edition)
and Canadian Electrical Code, CSA C22.1.