21 AFTER GENERAL OVERHAUL
21.1 Parameter modification with the condition monitoring unit
WARNING
Do NOT make any parameter changes with the condition monitoring unit
before the General Overhaul process is fully completed.
CAUTION
Recheck the condition monitoring unit display for possible new warnings after
you have done all parameter resettings that are listed in this chapter.
21.1.1 GO settings menu (Menu 7)
After General Overhaul, the parameters that are listed in the following table must be reset to the original value
(zero) unless otherwise indicated.
Menu 7 is accessible for users with password level 7.
Parameters to be reset to zero (0) after General Overhaul
Parameter
Name
Value
Description
7-6
RT slow
"nnnn" h
Run-time in slow speed
7-7
RT fast
"nnnn" h
Run-time in fast speed
7-8
No. OT
"nnnnn"
Number of hoist motor overtemperature incidents. Reset when the hoisting motor has been
replaced
7-9
No. OL
"nnnnn"
Number of hoist overload incidents
7-10
E-stops
"nnnnn"
Number of emergency stops
7-11
ST up
"nnnnn"
Number of starts in up direction
7-12
ST down
"nnnnn"
Number of starts in down direction
7-13
ST fast
"nnnnn"
Number of starts to fast speed (two-step control only)
7-14
Max ED
"nn" %
Maximum ED value
7-15
Over ED
"nnnnn"
Number of cases where ED value has exceeded the rated ED value
7-16
SRT3
"nnnnn"
Load sum with hoist running time, third power
7-17
SRT8
"nnnnn"
Load sum with hoist running time, eighth power
7-23
Max load
"nnnn" %
The maximum value of the measured load
7-24
Br Count
"nnnnn"
The brake wear counter. Counts the number of stop actions for the calculation of Br SWP%.
Reset when the hoisting brake has been replaced
WARNING
Do NOT reset or otherwise adjust parameters 7-18 (SL1), 7-19 (SL3) or 7-20
(SL8).
21.1.2 Design values menu (Menu 6)
Check that the parameters of Menu 6 have their original design values as listed in the following table. Reset the
parameter values to the original design values if necessary.
Menu 6 is accessible for users with password level 6.