15
AG-7.2.B1-092414 • Restricted - customer use only
3
SERVERS
Volicon, a division of Verizon Digital Media Services offers a number of different rack mounted
servers to meet customer requirements.
Figure: Typical MIP Server
3.1
Server Dimensions and Power Requirements
Server
Hard Drive
Storage
Capacity
Power Requirements
All supplies 50/60Hz
Height is multiple
1U, (1.74 inch,
44.45 mm)
Weight
Scout
Observer
1 bay
Single 200W
100-240V 4.2A
1U x 14.0” (346mm)
deep
12.8lbs
(6.8kg)
Enterprise
Observer
TS
4 RAID
hot swap
1 aux bay
Redundant Supplies
700W 100-140V 8.5-6.0A
750W 180-240V 5.0-3.8A
per supply
1U x 25.6” (650mm)
deep
36 lbs.
(16.3kg
Enterprise
Observer
TS
8 RAID
hot swap
1 aux bay
Redundant 700W Supplies
100-240V 10.0-4.0A per supply
2U x 25.5” (648mm)
52lbs
(26.6kg)
Observer
8 RAID
hot swap
1 aux bay
Redundant 800W Supplies
100-240V 10.0-4.0A per supply
3U x 25.5” (648mm)
deep
72lbs
(32.7kg)
Observer
16 RAID
hot swap
2 aux bays
Redundant 800W Supplies
100-240V 10.0-4.0A per supply
3U x 25.5” (648mm)
deep
72 lbs.
(32.7kg)
Observer
TS
24 RAID
Hot swap
2 aux bays
Redundant 900W Supplies 100-
240V 11.0-4.5A per supply
4U x 26.0” (660mm)
deep
75lbs
(34.0kg)
Table: Server Space and Power requirements
3.2
Mounting, Power, Basic Connections
Servers mount in standard 19-inch racks. Follow your rack manufacturer’s mounting instructions for
safe and stable mounting. If the server power supply has a 110/240 switch, make sure to set it to the
proper voltage 120/240VAC, 50/60 Hz.
Plan for your rack space and cooling requirements by creating a table similar to the one shown
above. List your servers, set top boxes, and related equipment. If possible, include a PC or laptop
dedicated for use with the MIP servers.