![Verizon Volicon MIP Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/verizon/volicon-mip/volicon-mip_admin-manual_1005053108.webp)
108
AG-7.2.B1-092414 • Restricted - customer use only
Enable strong
password policy
Enabling this option requires users to periodically reset
passphrase and use a combination of characters to create
strong passwords. The system will refuse to accept a
passphrase change if it does not meet the requirements and
will prompt the user with the requirements.
The criterion for password acceptance is:
1.
Minimum of eight characters
2.
One Upper case letter
3.
One lower case letter
4.
One number
5.
One symbol character
6.
NO REPEATING characters
(This feature is not currently implemented)
Email alerts sent
address
From email address used for email sent by Central Server.
Attached logo
Attach company logo to the alert email. Permissible file types:
JPG, GIF, PNG.
Table: Central Server – General Settings
11.3.2
Settings - SNMP Receivers
This section configures MIP to accept polling requests from the “Network Management Systems”
(NMS). The MIP SNMP implementation is read-only. The management console is able to query MIP
for status but not change settings via SNMP. MIP issues traps reporting unusual events to the
management console.
Figure: SNMP Receivers
Protocol
Enter the version your NMS uses. MIP supports SNMP v1 and
SNMP v2.
Community:
Password to establish connectivity with the SNMP receiver.
This is public by default (unrestricted access).