26
FAULT SYMPTOMS
1
Your Fanfare fire is designed and manufactured to give many years of trouble free
operation. In the unlikely event of any component failure or installation problem the
appliance will restore to a "fail-safe" condition. However, faults can be caused by
situations other than component failure and we strongly recommend that you consider
the following points when using your fire.
2
Since the air supply for the fire is drawn by a fan and extracted to the outside air along
with the spent products of combustion, it is inevitable that fluff, lint and even pet hairs
could stick to the fan blades in the flue system. Without regular cleaning during
maintenance checks this build up could slow down the fan to an extent that it may
cause the flue flow safety device to shut down the gas supply to the fire. This "nuisance"
shut down can be avoided by observing the servicing and maintenance
recommendations in the Installation Manual.
3
The fan unit is fitted with an electronic control unit that monitors the behaviour of the
fan during the start up procedure and in the event of high gusts of wind. When the fan
is switched on, the controller will set it to run at high speed until the air pressure
switch senses a satisfactory amount of air flow. Once the air flow has been proved the
fan will slow down to its operating speed. If a high gust of wind causes the pressure
switch to return to the 'no air' position, the controller will switch over to the high speed
setting to overcome the wind. The pressure switch will then switch back and the
controller will return the fan to its operating speed. In the event of the gust of wind
being more persistent, the controller will maintain the fan at high speed for
approximately 6 seconds. If the pressure switch has not sensed a return of airflow in
this time the controller will shut down the whole system. In this event the fire will go out
and will only relight if the ON switch on the switch panel is pressed.
4
When first switched on the fan may 'pulse' between the high and low operating speeds.
This is normal providing the fan runs at a steady speed after 10 -15 minutes of use with
the fire alight.
SPARE PARTS LIST
Replacement parts list is as follows;
Part Description
Switch frame Remote
Gas valve (NG Models)
V4-15
Gas valve (LPG Models)
V4-15
Solenoid valve
MSV/EE/2DO8
Oxypilot (NG Models)
OP 9017
Oxypilot (LPG Models)
OP 9214
Coals (23 off)
Supplier Ref. CR0001