Place the adaptor box against the wall, ensuring it correctly aligned with the flue spigot, 
and mark the position of the four fixing holes on the wall (See Figures 5 & 11) Drill and 
plug the wall in the appropriate positions. Remove the four M5 screws at the rear of the 
box and retain for use later. 

3   

Cut  a  slit  in  the  grommet  at  the  rear  of  the  box  and  feed  through  the  power  cable, 

ensuring that the connecting plugs are protected against damage. 

4   

Place the adaptor box against the wall and screw into position. 

5   

Remove  the  front  cover  from  the  fan  unit  and  withdraw  the  inner  fan  chassis,  as 
previously described.  Remove the four blanking plugs from the rear of the fan box and 
discard. 

6   

Cut  a  slit  in  the  grommet  at  the  rear  of  the  fan  unit  (not  the  side  grommet)  and  feed 
through  the  power  cable.  Push  the  fan  unit  into  the  adaptor  unit  and  secure  in  place 
using the four M5 screws provided. 

7   

Fit the gasket, connect the power cable and refit the fan chassis as previously described. 

8   

Seal the edges where the two boxes meet with silicon mastic. 

NOTE:  ON  BOTH  RECESSED  AND  SURFACE  MOUNTED  FAN  UNITS  THE  FAN  COVER 

ALSO  ACTS  AS  THE  TERMINAL  GUARD  AND  IT  IS  NOT  NECESSARY  TO  FIT  ANY 
ADDITIONAL  GUARD.  IF  REQUIRED  A  PROTECTIVE  CAGE  IS  AVAILABLE  TO 
SPECIAL ORDER. 

FITTING THE BURNER UNIT

 

1   

Check  that  the  ignition  system  functions  correctly.  Push  in  the  control  valve  and 
operate  the piezo  ignition mechanism  and check  that  a  spark  is  generated  at  the pilot 
burner. If no spark is evident, check the connections and the soundness of the leads. 

2   

Check tightness of nuts at the control-valve end of the thermocouple. 

CAUTION:

  Do not 

over-tighten. 

3   

Plug the connector on the solenoids on the underside of the burner unit to the mating 
plug on the switch frame of the fire.  

4   

Place the burner tray in position within the firebox. The tabs on either side of the rear of 
the  burner  should  be  pushed  on  to  the  brackets  on  the  firebox  and  then  the  burner 
fixed in place using the two screws on either side of the coal retainer. 

5   

Connect  the  gas  supply pipe  to  the  fire  using  the  nut  and  olive  provided.  Ensure  that 
the  gas  line  is  purged  before  connecting  the  pipe,  as  any  debris  left  in  the  pipe  will 
cause the appliance to malfunction if it enters the controls. 

 

Содержание NPFC/P00T/MN

Страница 1: ...URSELF PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON INSTALLATION SERVICING AND USERS INSTRUCTIONS including side venting installation instructions THESE PRODUCTS ARE APPROVED TO THE EUROPEAN GAS DIRECTIVE THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE ...

Страница 2: ...mpetent person 2 The fan on this appliance can only be serviced from outside the building The Installation Instructions must be adhered to without exception Table A DIMENSIONS mm A 320 B 500 C 490 D 585 E 350 F 525 G 132 H 27 Excluding Trim NOTE THE FAN UNIT MUST NOT BE INSTALLED AT A HEIGHT OF MORE THAN 1 4 METRES FROM GROUND LEVEL ...

Страница 3: ...o8 x 3 8 Screws c Middle ceramic 1 Brick Clamping Plate 1 Fan Spacer Roll of sealing tape 1 Bag of 23 coals 1 Magnetic Trim 1 Flue Duct 100mm x 50mm x 500mm Installation and Servicing Instructions Users Instructions Guarantee Card The fan spacer is supplied if ordered separately It will be required only if the rebate on the surround or the fake chimneybreast is less than 51mm 2 If fitted to a stan...

Страница 4: ...ed flame or incandescent part of the fire bed up to that wall d Have a thickness of not less than 12mm and a minimum height of 50mm along its front and side edges HOLE IN THE WALL INSTALLATIONS Where the appliance is installed in a hole in the wall fireplace a hearth as previously detailed for floor level fireplaces shall be fitted on the floor beneath the hole so as to protect combustible materia...

Страница 5: ...m F From an internal or external corner 200mm G Above ground or balcony level 300mm H From a surface facing the terminal 600mm I From a terminal facing a terminal 1200mm J From the opening in a carport 1200mm K Vertically from a terminal on the same wall 1500mm L Horizontally from a terminal on the same wall 300mm FITTING THE FIREBOX SURFACE FITTED 1 Note For surface fitting of the Fanfare the fir...

Страница 6: ...an box This can be achieved by drilling a 25mm diameter hole minimum though the wall adjacent to the hole for the flue duct When a core drill has been used to make the hole for the flue duct there is enough room to pass the cable through the same hole as the flue duct but care must be taken to prevent the cable coming in to contact with the flue duct If this method is used it is recommended that a...

Страница 7: ... to the marked length LESS 140mm See Figure 5 Refit the duct with the four screws provided 8 Refit the firebox and seal into the fireplace opening using the double sided tape supplied or alternatively a water based mastic sealant Note If installing without the fireplace in position when determining the length of flue spigot required allowance must be made for the depth of infill panel being used I...

Страница 8: ...e firebox From this point route a length of rigid or semi rigid pipe to the fire recess Care should be taken to sleeve the pipe when passing through masonry 3 The gas supply must be routed to the rear of the firebox The entry point is a grommeted hole 40mm above the hearth level and 45mm to the right of the centre line of the appliance when facing the wall it is to be fitted to Route the pipe unde...

Страница 9: ...sket in too far It need only be pushed in to a point where the edge of the gasket is level with the inner flue duct 7 Secure the cable gland to its bracket on the fan carrier See Figure 9 and then connect the power cable using the Molex snap connectors Replace the fan carrier and its gasket into the fan box and secure in place by locating the keyhole slots over the pan head screws at the rear of t...

Страница 10: ...apping screws should pass through the bushes from which the large screws were removed 5 Fit the gasket connect the power cable and refit the fan chassis as previously described 6 Seal the edges where the two boxes meet and where the spacer meets the wall with silicon mastic FITTING THE SURFACE MOUNTING ADAPTOR BOX 1 In cases where the fan unit is to be fitted on the surface of the outside wall an ...

Страница 11: ... meet with silicon mastic NOTE ON BOTH RECESSED AND SURFACE MOUNTED FAN UNITS THE FAN COVER ALSO ACTS AS THE TERMINAL GUARD AND IT IS NOT NECESSARY TO FIT ANY ADDITIONAL GUARD IF REQUIRED A PROTECTIVE CAGE IS AVAILABLE TO SPECIAL ORDER FITTING THE BURNER UNIT 1 Check that the ignition system functions correctly Push in the control valve and operate the piezo ignition mechanism and check that a spa...

Страница 12: ... be produced at the pilot electrode Note If the pilot does not light keep the knob depressed in the PILOT position for a short period of time this will purge any air in the system Once the air has been purged repeat step 2 as above 3 Keep the knob depressed for 10 15 seconds and the release The pilot flame should remain alight 4 If the pilot flame goes out repeat the process holding down the contr...

Страница 13: ...TS WARNING This product uses fuel effect pieces containing Refractory Ceramic Fibre RCF which are man made vitreous silicate fibres along with fibrous glass and mineral wool Excessive exposure to these materials may cause temporary irritation to eyes skin and respiratory tract consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a mini...

Страница 14: ... the coal lay may be required to obtain the maximum amount of realism ADJUSTMENT OF COALS 1 Relight the appliance and allow to burn for 10 12 minutes 2 Check the flame pattern and ensure that it is regular and natural looking Using a pair of tongs adjust the coals to regularise the pattern of flames Even small adjustments to the positions of the coals add greatly to the realism Figure 15 ...

Страница 15: ...rge pebble H so that it touches C and D and leans against the middle ceramic Place small pebble I on top of small pebble B and touching the middle ceramic Top Row Place two small pebbles J and K on top of the rear ceramic and push them back so that they touch the rear wall of the box They should be supported by pebbles G and H Place large pebble L next to J and K on top of the rear ceramic and sup...

Страница 16: ...pproximately 6 seconds If the pressure switch has not sensed a return of airflow in this time the controller will shut down the whole system In this event the fire will go out and will only relight if the ON switch on the switch panel is pressed When first switched on the fan may pulse between high and low operating speed settings This is normal providing the fan runs at a steady speed after 5 10 ...

Страница 17: ...30mm for fitting which may be achieved by using either a deep rebated mantel or a false chimney breast See Figure 17 and 18 3 There must be a minimum of 25mm clearance between the flue duct and any combustible material The fixing brackets are designed to provide both the method of supporting the lengths of flue duct and setting the 25mm clearance required 4 The flue duct may exit from either the l...

Страница 18: ...G SEE FIGURES 20 21 22 23 1 The order in which the various parts of the system are installed is not critical and the installer can decide which part to install first The following instructions give a suggested order that may or may not be adhered to 2 Connect the 500mm starter flue duct to the side of the firebox from the left or right hand side as required The blanking plate should be fixed to th...

Страница 19: ...F DUCTING IN PLACE AND SLIDE IN TO POSITION ENSURING THE JOINTING SLEEVE IS CORRECTLY POSITIONED ENSURE 3mm GAP IS LEFT BETWEEN ENDS OF THE DUCTING ENSURE SEALING GASKET IS POSITIONED BETWEEN DUCTING AND CONNECTING SLEEVE DRILL THROUGH THE HOLES IN THE SLEEVE WITH THE BIT PROVIDED AND SCREW TOGETHER USING THE SELF TAPPING SCREWS PROVIDED DUCT SEALING GASKET FIGURE 20 FIGURE 21 FIGURE 22 FIGURE 23 ...

Страница 20: ...he flue duct the cable can be hidden within the duct cladding If the supply is on the opposite side either enclosing in conduit or chasing in to the plaster should hide the cable 2 The 12 core grey fan cable should be routed to the fan unit along the support brackets as shown in Figure 24 The standard length of cable fitted to the firebox will normally only be sufficient for rear venting applicati...

Страница 21: ...IS FITTED 6 OTHER FITTINGS AVAILABLE 6 1 Every installation of a side venting Fanfare fire should have been surveyed and the correct fittings ordered before the installer goes on site and reads these instructions If the fittings supplied are not sufficient to complete the installation the pictures below show the options available CLADDING MATERIAL FIXING SCREWS INSULATION FIGURE 25 STANDARD STARTE...

Страница 22: ...h and pass completely along the top front edge of the opening 25mm down and 25mm inside A visual check should ascertain that all the smoke generated is drawn back into the flue BRIEFING THE USER 1 Demonstrate the full operation of the appliance to the user referring them specifically to the lay of the coals and removal of soot as described in the user instructions 2 Inform the user that all cleani...

Страница 23: ...rmal flue conditions This device is NOT a substitute for an independently mounted carbon monoxide detector During the summer when the appliance is not in use we recommend that it be turned on from time to time to get the fan running and some air passing across the electronic controls Fires which have been left inoperative throughout the summer months may exhibit fault conditions but these are ofte...

Страница 24: ... fan unit should be checked and inspected and the appliance serviced before further use In any event the flue and fan system should be checked annually to ensure continued clearance of combustion products and that there is no excessive build up of soot The decorative trim on the front of the fire is held in place with magnets Should you wish to clean the trim simply pull it off of the fire clean u...

Страница 25: ...ce on the appliance It must therefore be replaced annually After changing the pilot burner operate the spark generator and observe that the spark is satisfactory 5 Lay the burner on a flat surface and remove clean and replace the main injector 6 Any soot or debris should be removed from the fireplace and flue The flue should be inspected for soundness and a smoke test performed as described in the...

Страница 26: ...ind When the fan is switched on the controller will set it to run at high speed until the air pressure switch senses a satisfactory amount of air flow Once the air flow has been proved the fan will slow down to its operating speed If a high gust of wind causes the pressure switch to return to the no air position the controller will switch over to the high speed setting to overcome the wind The pre...

Страница 27: ...ts IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIII RECORD OF 5th SERVICE Serviced by 8888 CORGI No 8888 Service Date IIIII Signed I II I Comments IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII RECORD OF 6th SERVICE Serviced by 8888 CORGI No 8888 Service Date IIIII Signed I II I Comments IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIII RECORD OF...

Страница 28: ...28 B 114230 Issue 3 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com ...

Отзывы: