Push  in  and  turn  the  control  knob  to  the  SPARK  position,  and  hold  there  for  a  few 
seconds.  Continue  turning  anti-clockwise  through  the  spark  click  to  the  PILOT  light 

position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat. When the 
pilot lights after the spark, keep the knob depressed for approximately ten seconds.  
Now release the knob and the pilot should stay alight. If the pilot is extinguished during 

use,  wait  three  minutes  before  repeating  the  ignition  procedure.  To  achieve  the  HIGH 
setting, push the control knob in slightly and continue turning anti-clockwise to the high 

position.  The  main  burner  should  light  after  a  few  seconds.  To  decrease  the  setting  to 
LOW,  turn  the  control  knob  clockwise  to  the  low  setting.  To  turn  to  the  PILOT  position 
from the HIGH or LOW positions, press the control knob in, and return to the pilot position 

and release. To turn the fire OFF, keep the knob pressed in, return to the off position and 
release.  

Spark Failure 

The gap between the spark electrode and the pilot should be 3  - 5mm to produce a good 
spark.    There  should  be  no  need  to  adjust  this.    If  under  any  circumstances  the  piezo 

electric spark fails, the pilot cannot be lit manually.  

Setting The Pressure 

The  pressure  test  point  is  located  on  the  left  hand  side  of  the  appliance,  on  the  main 
burner pipe, next to the brass restrictor/connector. Release the setting pressure test point 
screw, and attach a U gauge. Light the fire on the HIGH setting.  
To commission the appliance, the burner pressure must be in accordance with the figures 
stated  in  the  data  section  of  these  instructions.  The  fire  is 

factory  set

  to  achieve  these 

pressures and any significant variation could indicate a supply problem. If the pressure is 
too high, the gas supply meter may be set incorrectly.  This should be checked with the fire 
running and if necessary reset by the gas supplier. If the burner pressure is too low, then 

check  the  inlet  pressure  with  the  appliance  running.  If  this  is  less  than  approximately 
20mbar it will need to be reset by the gas supplier. If the setting pressure is too low, but 

the  meter  pressure  is  acceptable,  then  a  problem  in  the  supply  pipework  is  to  be 
suspected.  This  will  be  dirt  and  debris,  kinked  or  inadequate  size  pipes,  restriction  in  a 
fitting, shut off elbow not fully open or solder flashing across a joint. Identify the cause of 

the  restriction  and  rectify.  Switch  the  fire  off,  disconnect  the  U  gauge  and  refit  the  test 
nipple  screw.  Light  the  fire  and  check  for  gas  soundness.  In  the  event  that  the  burner 

pressure  is  not  in  accordance  with  the  figures  stated  in  the  data  section  of  these 
instructions,  the  appliance  must  not  be  commissioned,  and  the  manufacturer  should  be 
contacted for guidance.  

Fitting The Trim 

Once the fire has been fully installed and tested the decorative trim can be hung on the 4 

front studs, offer up the trim to the fire, aligning the 4 studs the key hole slots on the back 
of the trim, push the trim back and then slide the trim down so the heads of the studs lock 
the trim securely, do not release the trim until you are sure it is fixed in place.   

Содержание Cupello

Страница 1: ...ON THE WALL FLUELESS GAS FIRE INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN...

Страница 2: ...products to provide a complete combustion system which is intrinsically safe The appliance must be installed by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 o...

Страница 3: ...iently ventilated space A minimum of 100cm 2 15 5 in 2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility of draughts e...

Страница 4: ...d that the old flue should be partially sealed off to prevent draughts however some ventilation will be required to prevent condensation The appliance is designed to be wall mounted It is possible to...

Страница 5: ...in the back panel of the appliance The appliance may be installed with or without a non combustible hearth If a hearth is fitted the size and design may be as desired A non combustible shelf of any d...

Страница 6: ...es from within the room which may over a period of time slightly discolour decorative surfaces above the fire Plaster Walls Some types of plastered walls may produce small cracks if there is any conce...

Страница 7: ...ply pipe and sleeving In order to avoid unnecessary pressure drops no more than 1 5m of 8mm diameter pipe must be used If a concealed gas connection is to be made the supply pipe should always be slee...

Страница 8: ...red which are not supplied with this product These should be constructed from metal and not plastic If a concealed gas connection is to be made ensure the gas supply pipe is in its final position and...

Страница 9: ...HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in the data section of these instructions The fire is factory set to achieve these pressures...

Страница 10: ...ot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble components 10 Turn on the gas supply and leak test Check pilot and burner for good ig...

Страница 11: ...ts they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seals will usually be required The per...

Страница 12: ...to provide a flow through the firebox The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from...

Страница 13: ...ean Spark shorting to metalwork under tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on...

Страница 14: ...NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is open Do not place any objects on top of th...

Страница 15: ...manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 50mm 2in Clearance to the front of the appliance is 500mm 20in The back of the app...

Страница 16: ...ly ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push...

Страница 17: ...a replacement part is required please contact your stockist in order to obtain the correct part As our policy is one of continuous improvement and development we hope therefore you will understand we...

Страница 18: ...2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19 BLANK PAGE...

Страница 20: ...20 VERINE LIMITED 52 Broton Drive Trading Estate Halstead Essex CO9 1HB TEL 01787 472551 FAX 01787 476589 www verine co uk sales verine co uk THIS BOOKLET CONTAINS 20 PAGES CUPELLO 06 06 II UI...

Отзывы: