9
Push in and turn the control knob to the SPARK position, and hold there for a few
seconds. Continue turning anti-clockwise through the spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat. When the
pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If the pilot is extinguished during
use, wait three minutes before repeating the ignition procedure. To achieve the HIGH
setting, push the control knob in slightly and continue turning anti-clockwise to the high
position. The main burner should light after a few seconds. To decrease the setting to
LOW, turn the control knob clockwise to the low setting. To turn to the PILOT position
from the HIGH or LOW positions, press the control knob in, and return to the pilot position
and release. To turn the fire OFF, keep the knob pressed in, return to the off position and
release.
Spark Failure
The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good
spark. There should be no need to adjust this. If under any circumstances the piezo
electric spark fails, the pilot cannot be lit manually.
Setting The Pressure
The pressure test point is located on the left hand side of the appliance, on the main
burner pipe, next to the brass restrictor/connector. Release the setting pressure test point
screw, and attach a U gauge. Light the fire on the HIGH setting.
To commission the appliance, the burner pressure must be in accordance with the figures
stated in the data section of these instructions. The fire is
factory set
to achieve these
pressures and any significant variation could indicate a supply problem. If the pressure is
too high, the gas supply meter may be set incorrectly. This should be checked with the fire
running and if necessary reset by the gas supplier. If the burner pressure is too low, then
check the inlet pressure with the appliance running. If this is less than approximately
20mbar it will need to be reset by the gas supplier. If the setting pressure is too low, but
the meter pressure is acceptable, then a problem in the supply pipework is to be
suspected. This will be dirt and debris, kinked or inadequate size pipes, restriction in a
fitting, shut off elbow not fully open or solder flashing across a joint. Identify the cause of
the restriction and rectify. Switch the fire off, disconnect the U gauge and refit the test
nipple screw. Light the fire and check for gas soundness. In the event that the burner
pressure is not in accordance with the figures stated in the data section of these
instructions, the appliance must not be commissioned, and the manufacturer should be
contacted for guidance.
Fitting The Trim
Once the fire has been fully installed and tested the decorative trim can be hung on the 4
front studs, offer up the trim to the fire, aligning the 4 studs the key hole slots on the back
of the trim, push the trim back and then slide the trim down so the heads of the studs lock
the trim securely, do not release the trim until you are sure it is fixed in place.
Содержание Cupello
Страница 19: ...19 BLANK PAGE...