16
A supply of fresh air into the room is advisable to maintain temperatures within limits.
The appliance MUST NOT be installed in a bedroom or bathroom.
For Republic of Ireland, see relevant rules in force.
The room size should be a minimum of 30m
3
(e.g. 11’6” x 11’6” x 8’) to allow adequate
circulation of air and ensure the correct operation of the fire. This volume may include
adjacent spaces but these spaces must not be separated by a door. To calculate a room
size in cubic metres (m
3
) divide the room volume in cubic feet (ft
3
) by 35.3.
This appliance is intended as a secondary source of heat only and should not be used
in a room without some form of background heating present.
Operating The Appliance.
The pilot is visible behind the left hand side of the burner.
The control knob is located on the lower right hand side of the outer case. It is of a
spherical design and is marked as shown in the diagram below;
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
Push in and turn the control knob to the SPARK position, and hold there for a few
seconds. Continue turning anti-clockwise through the spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat. When the
pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If the pilot is extinguished during
use, wait three minutes before repeating the ignition procedure. To achieve the HIGH
setting, push the control knob in slightly and continue turning anti-clockwise to the high
position. The main burner should light after a few seconds. To decrease the setting to
LOW, turn the control knob clockwise to the low setting. To turn to the PILOT position
from the HIGH or LOW positions, press the control knob in, and return to the pilot position
and release. To turn the fire OFF, keep the knob pressed in, return to the off position and
release.
Combustion And Monitoring System
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts
down during use for no apparent reason then several reasons may be suspected. If a door
or window has been opened creating a draught, then pilot disturbance could be the
problem and removal of the draught should resolve this. The appliance can then be re-lit
in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation.
Switch the appliance OFF, call in your installer to check the appliance and ventilation.
Remedial work must be carried out as required. DO NOT allow the appliance to be used
until the appliance and installation is passed as safe. If the pilot continues to be
extinguished, you must call your installer to check the operation of the complete
appliance.