Verine Cupello Скачать руководство пользователя страница 4

 

Appliance Data. 

 

Gas  Group  Country(s)  of 

destination  

G20 Natural Gas CAT I2H GB/IE  

Inlet Pressure  

20 mbar  

Max Energy Input  

Gross 2.6 kW  

 

Net 2.35 kW  

Max Gas Rate  

0.25 m3/h  

Min Energy Input  

Gross 1.5 kW  

 

Net 1.35 kW  

Pilot Energy Input  

Gross 166 W  

 

Net 150 W  

Burner Pressure High  

13.5 mbar. (+/-0.75 mbar). Hot  

 

13.0 mbar. (+/-0.75 mbar). Cold  

Low  

4.2 mbar. (+/-0.25 mbar). Hot  

 

3.7mbar (+/-0.25 mbar). Cold  

Main burner flow restrictor   Stereo 1.30mm (1/4” BSP)  
Oxypilot  

SIT/Bray 9082  

Gas Inlet Connection  

8mm inlet restrictor elbow  

Ignition  

Piezo spark  

Spark Gap  

4.0 mm (± 1.0mm)  

 

Please see Data Badge affixed to appliance for current data. This appliance is for use only 
with the gas type, and at the pressure stated on the appliance Data Badge. 

Installation Requirements. 

This appliance may be installed with or without a hearth. If a hearth is fitted, the size and 
design  may  be  as  desired.  If  the  appliance is  to  be  sited  near  a disused  natural  draught 

flue it is recommended that the old flue should be partially sealed off to prevent draughts, 
however some ventilation will be required to prevent condensation.  
The appliance is designed to be wall mounted. It is possible to install  the appliance onto 

certain  types  of  combustible  materials  -  see  section  entitled  ‘Clearances  to  combustible 
materials’.  

 

In  the  event  that  the  fire  is  sited  near  a  disused  or  unserviceable  fireplace  served  by  a 
natural  draught  flue,  any  existing  under  grate  draught  device  should  be  sealed  off  to 
prevent  loss  of  heat  or  creation  of  draughts.  The  passageway  into  the  flue  should  be 

partially sealed to prevent excessive draughts, however some ventilation will be required in 
the  old  flue  to  prevent  condensation  and  dampness.  Advice  should  be  sought  from  your 

local building control officer. 

 

Room Sizing 

The  room  size  should  be  a  minimum  of  30m

(e.g.  11’6”  x  11’6”  x  8’)  to  allow 

adequate circulation of air and ensure the correct operation of the fire. This volume 
may include adjacent spaces  but these spaces  must not be separated  by a door. To 
calculate a room size in cubic metres (m

3

) divide the room volume in cubic feet (ft

3

by 35.3.  

Содержание Cupello

Страница 1: ...ON THE WALL FLUELESS GAS FIRE INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN...

Страница 2: ...products to provide a complete combustion system which is intrinsically safe The appliance must be installed by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 o...

Страница 3: ...iently ventilated space A minimum of 100cm 2 15 5 in 2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility of draughts e...

Страница 4: ...d that the old flue should be partially sealed off to prevent draughts however some ventilation will be required to prevent condensation The appliance is designed to be wall mounted It is possible to...

Страница 5: ...in the back panel of the appliance The appliance may be installed with or without a non combustible hearth If a hearth is fitted the size and design may be as desired A non combustible shelf of any d...

Страница 6: ...es from within the room which may over a period of time slightly discolour decorative surfaces above the fire Plaster Walls Some types of plastered walls may produce small cracks if there is any conce...

Страница 7: ...ply pipe and sleeving In order to avoid unnecessary pressure drops no more than 1 5m of 8mm diameter pipe must be used If a concealed gas connection is to be made the supply pipe should always be slee...

Страница 8: ...red which are not supplied with this product These should be constructed from metal and not plastic If a concealed gas connection is to be made ensure the gas supply pipe is in its final position and...

Страница 9: ...HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in the data section of these instructions The fire is factory set to achieve these pressures...

Страница 10: ...ot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble components 10 Turn on the gas supply and leak test Check pilot and burner for good ig...

Страница 11: ...ts they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seals will usually be required The per...

Страница 12: ...to provide a flow through the firebox The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from...

Страница 13: ...ean Spark shorting to metalwork under tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on...

Страница 14: ...NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is open Do not place any objects on top of th...

Страница 15: ...manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 50mm 2in Clearance to the front of the appliance is 500mm 20in The back of the app...

Страница 16: ...ly ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push...

Страница 17: ...a replacement part is required please contact your stockist in order to obtain the correct part As our policy is one of continuous improvement and development we hope therefore you will understand we...

Страница 18: ...2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19 BLANK PAGE...

Страница 20: ...20 VERINE LIMITED 52 Broton Drive Trading Estate Halstead Essex CO9 1HB TEL 01787 472551 FAX 01787 476589 www verine co uk sales verine co uk THIS BOOKLET CONTAINS 20 PAGES CUPELLO 06 06 II UI...

Отзывы: