4
Appliance Data.
Gas Group Country(s) of
destination
G20 Natural Gas CAT I2H GB/IE
Inlet Pressure
20 mbar
Max Energy Input
Gross 2.6 kW
Net 2.35 kW
Max Gas Rate
0.25 m3/h
Min Energy Input
Gross 1.5 kW
Net 1.35 kW
Pilot Energy Input
Gross 166 W
Net 150 W
Burner Pressure High
13.5 mbar. (+/-0.75 mbar). Hot
13.0 mbar. (+/-0.75 mbar). Cold
Low
4.2 mbar. (+/-0.25 mbar). Hot
3.7mbar (+/-0.25 mbar). Cold
Main burner flow restrictor Stereo 1.30mm (1/4” BSP)
Oxypilot
SIT/Bray 9082
Gas Inlet Connection
8mm inlet restrictor elbow
Ignition
Piezo spark
Spark Gap
4.0 mm (± 1.0mm)
Please see Data Badge affixed to appliance for current data. This appliance is for use only
with the gas type, and at the pressure stated on the appliance Data Badge.
Installation Requirements.
This appliance may be installed with or without a hearth. If a hearth is fitted, the size and
design may be as desired. If the appliance is to be sited near a disused natural draught
flue it is recommended that the old flue should be partially sealed off to prevent draughts,
however some ventilation will be required to prevent condensation.
The appliance is designed to be wall mounted. It is possible to install the appliance onto
certain types of combustible materials - see section entitled ‘Clearances to combustible
materials’.
In the event that the fire is sited near a disused or unserviceable fireplace served by a
natural draught flue, any existing under grate draught device should be sealed off to
prevent loss of heat or creation of draughts. The passageway into the flue should be
partially sealed to prevent excessive draughts, however some ventilation will be required in
the old flue to prevent condensation and dampness. Advice should be sought from your
local building control officer.
Room Sizing
The room size should be a minimum of 30m
3
(e.g. 11’6” x 11’6” x 8’) to allow
adequate circulation of air and ensure the correct operation of the fire. This volume
may include adjacent spaces but these spaces must not be separated by a door. To
calculate a room size in cubic metres (m
3
) divide the room volume in cubic feet (ft
3
)
by 35.3.