Verine Cupello Скачать руководство пользователя страница 14

 

14 

User Instructions. 
Important Notes. 

The installation and Servicing of this fire MUST only be carried out by a competent person 
(such as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) 
Regulations  1998,  the  relevant  British  Standards,  Codes  of  Practice,  the  Building 

Regulations and the manufacturer's instructions.  
Failure  to  comply  with  the  above  recommendations  could  lead  to  prosecution  and 

invalidate the appliance warranty.  
Always keep a note of the installer's name and address, CORGI registration number, the 
original  purchase  receipt  and  the  date  of  installation  for  future  reference.  Failure  to 

produce these documents may invalidate the warranty.  
The  appliance  should  be  serviced  regularly  to  ensure  continued  safe  operation.  See  the 

servicing section for further reference.  
Parts of this appliance become naturally hot during use. It is recommended that a suitable 
fireguard conforming to BS 8423 is used, especially where young children, pets, the elderly 

or infirm are concerned.  
The  manufacturer  of  this  appliance  considers  all  surfaces  as  working  surfaces  with  the 

exception of the control knob. 
Combustible items, such as flooring and furniture and soft wall coverings (such as blown 
vinyl or embossed paper), low temperature surrounds etc may discolour if fitted too close 

to  the  fire.    See  relevant  section  for  further  details  on  clearances  to  combustibles.  No 
combustible materials or flooring should protrude onto the hearth (if fitted).  
This appliance incorporates a combustion monitoring system (ODS).  
DO  NOT  burn  any  foreign  material  on  this  fire.  Under  no  circumstances  shall  the 
appliance be used if the glass front door or panel has been removed, damaged or is open.  
Do not place any objects on top of the appliance.  
The integral catalyst should be checked by the installer upon servicing to ensure there are 

no defects or obstructions that may prevent the satisfactory flow of combustion products.  
The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After 
this time the catalyst should be replaced.  
This appliance is only suitable for the gas type for which it is supplied.  

WARNING

: Due to the nature of this product the area around the top of the appliance (i.e. the 

grille) gets very hot. Care should be taken when operating the appliance.  

Clearances To Combustibles 

Combustible materials are defined as wood, fabrics, or other materials likely to combust if 

exposed  to  flame. Generally,  any  material,  which is  likely to  discolour,  melt  or  misshape 
when  exposed  to  moderate  heat,  should  be  considered  as  a  combustible  material  or 

surface.  
Clearance  to  the  sides  of  the  appliance  are  100mm  (4in)  but  curtains,  drapes  and  other 
fabrics are not permitted within a distance of 500mm (20in) of the appliance sides. 
No such materials are permitted directly above the appliance regardless of distance.  
The minimum clearance to the ceiling above the appliance is 800mm measured from the 

top of the appliance glass window panel (not the large glass fascia).  
Combustible materials should not be positioned directly in front of the appliance within a 
distance of 1Mtr.  
Under no circumstances should any electrical equipment e.g. plasma screen TV sets etc. 
be  positioned  on  the  wall  above  the  appliance.  The  appliance  is  designed  to  be  wall 

Содержание Cupello

Страница 1: ...ON THE WALL FLUELESS GAS FIRE INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN...

Страница 2: ...products to provide a complete combustion system which is intrinsically safe The appliance must be installed by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 o...

Страница 3: ...iently ventilated space A minimum of 100cm 2 15 5 in 2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility of draughts e...

Страница 4: ...d that the old flue should be partially sealed off to prevent draughts however some ventilation will be required to prevent condensation The appliance is designed to be wall mounted It is possible to...

Страница 5: ...in the back panel of the appliance The appliance may be installed with or without a non combustible hearth If a hearth is fitted the size and design may be as desired A non combustible shelf of any d...

Страница 6: ...es from within the room which may over a period of time slightly discolour decorative surfaces above the fire Plaster Walls Some types of plastered walls may produce small cracks if there is any conce...

Страница 7: ...ply pipe and sleeving In order to avoid unnecessary pressure drops no more than 1 5m of 8mm diameter pipe must be used If a concealed gas connection is to be made the supply pipe should always be slee...

Страница 8: ...red which are not supplied with this product These should be constructed from metal and not plastic If a concealed gas connection is to be made ensure the gas supply pipe is in its final position and...

Страница 9: ...HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in the data section of these instructions The fire is factory set to achieve these pressures...

Страница 10: ...ot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble components 10 Turn on the gas supply and leak test Check pilot and burner for good ig...

Страница 11: ...ts they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seals will usually be required The per...

Страница 12: ...to provide a flow through the firebox The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from...

Страница 13: ...ean Spark shorting to metalwork under tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on...

Страница 14: ...NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is open Do not place any objects on top of th...

Страница 15: ...manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 50mm 2in Clearance to the front of the appliance is 500mm 20in The back of the app...

Страница 16: ...ly ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push...

Страница 17: ...a replacement part is required please contact your stockist in order to obtain the correct part As our policy is one of continuous improvement and development we hope therefore you will understand we...

Страница 18: ...2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19 BLANK PAGE...

Страница 20: ...20 VERINE LIMITED 52 Broton Drive Trading Estate Halstead Essex CO9 1HB TEL 01787 472551 FAX 01787 476589 www verine co uk sales verine co uk THIS BOOKLET CONTAINS 20 PAGES CUPELLO 06 06 II UI...

Отзывы: