12
To position the external grids, proceed as follows:
-
Fit the small eyelet of the spring, with the long stem, on
the cap pin (on both connectors) (fig. 10.2).
-
Fit the two caps (with spring) from the front part of the
external grid, on the two housings pulling until a click
is heard (fig. 10.3) and attach the two chains to the
large eyelet of the spring.
-
Using one hand, grip the two chains connected to the
grid.
-
Bend the external grids back, gripping these with your
free hand where the bend is and introducing your
fingers inside the single fins (fig. 10/4).
-
Introduce your arm into the pipe until the grid
protrudes completely outwards.
-
Allow the grid to reopen, being careful to keep your
fingers inside the fins.
-
Turn the grid until the fins are fully horizontal and
tilted towards the outside.
-
Pull the chain, tensioning the spring, and fasten the ring
of the chain onto the pin of the inner washer (fig,11).
-
Using a pair of nippers, cut the excess chain links
(fig.12).
Warning: If the external grille is accessible , to prevent
the hazards resulting from its possible removal
(insertion of the hands into the pipes and touching the
powered parts), it is absolutely essential to fasten it to
the wall with 4 screws with a diameter of 6mm.
2.3.4
Power supply connection.
The air conditioner is equipped with a power supply cable
for connection to a switched fused outlet.
WARNING: The appliance must be EARTHED.
Refer to rating plate for voltage
.
All installations and wiring must be supervised by a
qualified electrician.
Installations and wiring must conform to the current
edition of BS 7671 (IE wiring regulations)
Warning
: this appliance must be connected to a double
pole fused (13A) isolating switch which can be switched
off when not in use. Switches should maintain a contact
separation of at least 3mm in all poles.
Important:
The wires in the mains lead fitted to the appliance are
coloured in accordance with the following code:
GREEN AND YELLOW = EARTH
BLUE
= NEUTRAL
BROWN
= LIVE
Should the mains lead ever require replacement it is
essential that this operation be carried out by a qualified
electrician. It should be replaced with a cable of adequate
size (minimum 1.5mm
2
cross section)
Caution
: these operations should be performed with the
machine already positioned on the bracket.
Содержание 91154AA