3-16
W A N s u i t e 6 4 5 0
ES
Sets the Errored Seconds (ES) threshold. An ES is a 1-second period in which
at least one logic error occurred. The default value is 45 seconds.
SES
Sets the Severely Errored Seconds (SES) threshold. An SES is a 1-second
period in which at least 320 CRC errors or one Out -of-Frame (OOF) error
occurred. The default value is 5 seconds.
LOSS
Sets the Loss of Signal Seconds (LOSS) threshold. A LOSS is 1-second
period in which the T1/E1 received signal is interrupted. The default value is
5 seconds.
UAS
Sets the Unavailable Seconds (UAS) threshold. A UAS is a 1-second period
in which consecutive severely errored seconds cause an unavailable state. The
default is 0 seconds (Disabled).
CSS
Sets the Controlled Slip Seconds (CSS) threshold. The default is 0 seconds
(Disabled).
BPVS
Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a 1-
second period in which at least one bipolar violation occurred. The default is
0 seconds (Disabled).
OOFS
Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default value is 5 seconds.
AISS
Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a 1-
second period when unframed all ones are received. The default is 0 seconds
(Disabled).
RAS
Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by
the terminal equipment when an improper signal is received from the facility
(or upon receipt of unframed all ones). The default is 0 seconds (Disabled).
Reset Timer
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset.
The CBR screens provide the user-activated buttons described below.
CAUTION:
Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.
Button
Function
Submit
Sets any values that have been changed.
Clear Alarms
Resets the alarm conditions and counts to zero.
Performance
Displays a Performance/Summary screen that shows a current
count of the number of error events that have occurred over the
past 24 hours and the past 30 days.
Содержание WANsuite 6450
Страница 1: ...i WANsuite 6450 Reference Manual April 2003 34 00326 C...
Страница 4: ...iv W A N s u i t e 6 4 5 0...
Страница 10: ...x W A N s u i t e 6 4 5 0...
Страница 14: ...xiv W A N s u i t e 6 4 5 0...
Страница 24: ...1 10 W A N s u i t e 6 4 5 0...
Страница 28: ...2 4 W A N s u i t e 6 4 5 0...
Страница 190: ...4 82 W A N s u i t e 6 4 5 0...
Страница 200: ...A 10 W A N s u i t e 6 4 5 0...
Страница 204: ...B 4 W A N s u i t e 6 4 5 0...