25
CLEANING
1.
Before cleaning the pump, wear rubber gloves and protective glasses.
2.
While CIP and SIP process, do not touch the pump and pipelines.
3.
Ensure velocity rate of CIP solutions is adequate to clean entire circuit. For most applications
a velocity of 1.52 m/sec is sufficient. For the CIP solution to achieve the proper velocity, the
pump drive must have enough speed range and horsepower. The required inlet pressure also
must be satisfied. If the pump does not supply enough CIP solution velocity, a separate CIP
supply pump with an installed bypass may be used.
4.
Refer to the below CIP and SIP process.
Содержание JEC JRZP Series